Battery operation

When the module is operating on battery, the following information is shown on the display:
 Time: xx:xx with the central ":" flashing.
 Day of the week, if a day of the week is flashing this means that regeneration is enabled for that day.
 If the programmed regeneration mode is volumetric (delayed or immediate), the time of day and
remaining available volume are displayed alternatively.
 The battery icon is
During battery operation, regeneration is not carried out and it is not possible to modify parameters.
4.4.7

End of cycle search

When searching for the end of the cycle, the controller displays the message F1-| or F2-| where the number
indicates whether the first or second attempt is being made to find the end of the cycle. A revolving bar is also
displayed to indicate that the motor is on. If both searches fail, the message FR01 is displayed.
4.4.8

Salt Alarm function

The controller generates a salt alarm using two different methods.
Method 1. The presence of salt is detected by a ON-OFF salt sensor (ON when the tank contains salt, OFF
when the tank does not contain salt). As soon as the sensor is set to OFF, the salt alarm icon is activated on
the display (in three languages: French, German and English). As soon as the sensor is restored to ON status
(i.e. the brine tank has been filled with salt), the salt alarm icon disappears from the display and the controller
enables regeneration.
Method 2. Activated only if the salt sensor is not installed. The controller incorporates a counter that is
decreased by one unit at each regeneration. As soon as the counter reaches zero, the salt alarm icon is
activated on the display (in three languages: French, German and English) and any regeneration is postponed
until the alarm has been manually desactivated. Once the alarm is removed, the controller will start any
postponed regeneration. Press any key to exit alarm. See parameter SA in advanced programming mode. If
during the service the
will show SAL to confirm that.
Transition from one mode to another is fully automatic. Electrical connection of the salt sensor instantaneously
activates method 1, otherwise method 2 is active.
displayed
Battery operation status
button is pressed for 5 seconds the salt alarm count down will be restored, display
43