Unit of measurement. Press buttons
litres; ΠC= m3; GL= gallons).
The option is displayed only if SH: 2 or SH: 3.
Remote regeneration start mode: In case a remote regeneration is initiated, this can be
an immediate regeneration if Sr is set to 0, or a delayed regeneration (starting at the
programmed time) if Sr is set to 1. To change the value, use the
buttons. Push the Regeneration button to confirm.
Daily water consumption per user. Press
requirement per user (e.g. 99 units of volume per user). Push the Regeneration button
to confirm.
Duration of the first regeneration step in minutes.
Duration of the second regeneration step in minutes.
Duration of the third regeneration step in minutes.
Duration of the fourth regeneration step in minutes.
Chlorine cell control enablement. Press
of the chlorine producer cell control. For the boards without chlorine cell management
hardware, even if the chlorine control is enabled, there won't be power in the back
terminal ports 7-8, so is not possible to produce Cl.
and
to set the unit of measure (Lt=
or
to set the daily water volume
and
buttons to enable operation
52
Lt
Lt – MC –
GL
0
0 – 1
OFF
OFF – 999
5
OFF – 99
30
OFF – 99
5
OFF – 99
5
OFF – 99
OFF
OFF – ON