S F E - E V
DATA
E
N
G
L
I
S
H
DESCRIPTION
Enter password, to change the figure press the
key to move from one parameter to the next.
Setting the time. The current time, the selected figure and the regeneration
symbol flash while the current date is fixed. To change the figure press the
key. Press the
key to move from one figure to the next
Day of the week. The current day flashes on the display and the time is
fixed. To change the selection, use the
Regeneration Start time for time clock regeneration, volumetric delayed
regeneration, calendar override initiated regeneration. If the programmed
regeneration mode is an Interval mode, the first regeneration will start at
that programmed time. Use the UP arrow to modify the digit, press the
DOWN arrow to switch to the next digit and press the regeneration button to
confirm and switch to next parameter.
Number of users. To set the number of users, Use the UP and DOWN arrows
to modify the value and press the regeneration button to confirm and switch
to next parameter.
Number of days remaining before the controller starts a regeneration based
upon the number of people in the house. Dr 3 indicates that if in 3 days no
regeneration occurred, the controller will start a regeneration. This
parameter is displayed only if the nP parameter is not set to off (OF in the
controller).
Regeneration mode that is currently programmed.
This parameter is only displayed in the basic menu, it can be modified only in
the advance programming menu.
Diplay Units type.
Lt for liters, MC for m3 and GL for gallons.
Depending on the choosen unit will the remaining volume be shown in liter,
cubic meter or gallon. This has however no influence on the unit to be used
when programming: always L for the resin volume, °f & °f xm3 or °d & °d
xm3 for the hardness and exchange capacity
48
DEFAULT
key. Press the
00:00
1
keys
2:00
OF
(off)
Lt
MIN –
MAX
00:00
23:59
1 – 7
00:00
23:59
OF – 9
Lt, MC,
GL