BFT LIBRA-C-LX Instrucciones De Instalación página 13

Cuadro de mandos
Ocultar thumbs Ver también para LIBRA-C-LX:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
Press the OK key
Control unit software version
N. total manoeuvres (x 100)
N. manoeuvres since latest maintenance (x 100)
N. radio control devices memorised
- +
- +
- +
- +
LIMIT SWITCH ADJUSTMENT
ACCESS TO MENUS Fig. 1
+/-
OK
OK
DIAGNOSTICS
OK
OK
OK
OK
* = 0,1,...,9,A,B,C,D,E,F
See PARAMETERS MENU
See LOGIC MENU
See RADIO MENU
OK
OK
DIAGNOSTICS and WARNINGS
DESCRIPTION
CODE
photocell test anomaly
safety edge test anomaly
photocell test anomaly
during opening
photocell test anomaly
during closing
*
hardware anomaly
encoder anomaly
*
*
amperostop anomaly
*
thermal cutout anomaly
*
communication anomaly
no-power anomaly
(restart)
bu er battery power
anomaly
power out-of-range
anomaly
Scroll up
Scroll down
Confirm/Switch on display
Exit Menù
NOTES
check photocell connection and/or
parameter/logic settings
check safety edge connection and/or
parameter/logic settings
check photocell connection during OP
and/or parameter/logic settings
check photocell connection during CL
and/or parameter/logic settings
check connections to motor
motor is moved manually and/or check
encoder and relevant wiring
make sure movement is not hindered
allow automated device to cool
check connection with accessory devices
and/or expansion boards or serial-con-
nected devices
there was a power loss. Board is now
active again
automated device running on battery
power
supply voltage not in 230V+/-10% range
LIBRA-C-LX - 13