BFT LIBRA-C-LX Instrucciones De Instalación página 17

Cuadro de mandos
Ocultar thumbs Ver también para LIBRA-C-LX:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
TABLE "A" PARAMETERS MENU -
Logic
min.
max.
0
180
0,1
100
0,1
100
1
180
1%
99%
1%
99%
0%
99%
1%
99%
1%
99%
0
129
TABLE "B" LOGIC MENU -
Logic
Default De nition
Automatic Closing
OFF
Time
OFF
Opening Impulse lock
OFF
Impulse lock TCA
OFF
Impulse lock on closing
OFF
Ram blow on opening
OFF
Ram blow in closing
OFF
2-step, 4-step logic
OFF
3-step logic
OFF
Pre alarm
INSTALLATION MANUAL
Default
Personal
De nition
Automatic Closing
40
Time
3
Opening delay time
3
Closing delay time
Time-to-clear traffic
40
light zone
10%
Motor 1 torque
10%
Motor 2 torque
20%
Slow-down speed
20%
Slow-down space
50%
Pedestrian opening
0
Zone
Cross out
setting
used
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Description
Set the numerical value of the automatic closing time from 0 to 180 seconds.
Set the opening delay time for motor 1 relative to motor 2, between 0,1 and 100
seconds. Adjust the time lag so that the minimum distance between the leaves,
when both are moving, is 50 cm.
Impostare il ritardo di chiusura del motore 2 rispetto al motore 1, regolabile da
0,1 a 100 secondi. Adjust the time lag so that the minimum distance between
the leaves, when both are moving, is 50 cm.
Set the desired time-to-clear for the zone run through by tra c controlled by the
tra c light, in the range 1 to 180 seconds.
Set the numerical value of the motor 1 torque between 1% and 99%.
This parameter denotes sensitivity to the obstacle (couple=1 maximum sensitivity).
Set the numerical value of the motor 1 torque between 1% and 99%.
This parameter denotes sensitivity to the obstacle (couple=1 maximum sensitivity).
Imposta la percentuale della velocità di rallentamento tra 0% e 99% della velocità
normale.
N.B. il valore 0 non e ettua il rallentamento dei motori.
Set the slow-down percentage between 1% and 99% with respect to the com-
plete manoeuvre.
Set the partial opening percentage for motor 2.
Set the zone number between a minimum value of 0 and a maximum value of
129.
The zone number allows you to create groups of automated devices, each of which
answers to the Zone Master. Each zone can have only one Master. The Master of
zone 0 also controls the Masters and Slaves of the other zones.
Description
Activates automatic closing
Excludes automatic closing
The Start impulse has no e ect during the opening phase.
The Start impulse becomes e ective during the opening phase.
The Start impulse has no e ect during the TCA dwell period.
The Start impulse becomes e ective during the TCA dwell period.
The start impulse has no e ect during the closing stage.
The start impulse is e ective during the closing stage.
It pushes for approx. 2 seconds in closing direction before opening. This allows the electric
lock to be released more easily.
IMPORTANT - When no adequate mechanical backstops are installed, do not use this function.
Excludes the ram blow in closing.
Before closing completely, the gate pushes for approx. 2 seconds as it opens. This allows
the solenoid lock to be released more easily.
IMPORTANT - When no adequate mechanical backstops are installed, do not use this function.
Excludes the ram blow in closing.
Enables 2-step logic (prevails over "3-step logic").
Enables 4-step logic when the 3-step logic is set to OFF.
Enables 2-step logic
(prevails over "3-step
logic").
closed
Enables 4-step logic
when the 3-step logic
on closing
is set to OFF.
open
on opening
after stop
The blinker comes on about 3 seconds before the motor starts.
The blinker comes on at the same time as the motor starts.
A start impulse has the following e ects:
2 steps
3 steps
opens
opens
closes
closes
stop + TCA
opens
opens
4 steps
opens
stop
closes
stop + TCA
opens
LIBRA-C-LX - 17

Publicidad

Tabla de contenido
loading

Tabla de contenido