Specifications of the radiator:
CAT C
: A device satisfying the standard NF Electricity Performance in
accordance with the criteria of the category indicated.
IP24
: Device protected against penetration of foreign solid bodies
and water splashes.
Classe II : Double insulation (no connection to earth).
PREPARE THE RADIATOR INSTALLATION
- This device has been designed to be installed in residential premises. In
all other cases, please consult your dealer.
- The installation must be done in accordance with the rules of the trade
and in conformity with standards in force in the country of installation
(NFC 15100 for France).
- If you have a wall covering installed on foam, a wedge must be put
under the device support of a thickness equal to that of the foam in order
to maintain a free space behind so as not to disturb its regulation.
Do not install the device:
- In a draught which is likely to disturb its regulation (subject to a
Centralised Mechanical Ventilation system, etc).
- Under a fixed current socket.
- In volume 1 in bathrooms.
Devices used in bathrooms must be installed in such a manner that the
switches and the other control devices of the device cannot be touched
by a person in the bathroom or the shower.
- Respect the minimum distances with the furniture for the placing of the
device.
Horizontal Model
Dimensions en cm
Installation
50
15
12
Vertical Model
15
30
23