4. MAIN PARAMETERS.
Input voltage Range
Rated input capacity (KVA)
Rated input power (KW)
Recommended fuse capacity (A)
Rated output (A/V)
Rated duty cycle (%)
No-load voltage (V)
Insulation class
Cooling mode
Protection class
Overall size (mm)
Weight (kg)
Welding current range (A)
Arc ignition current range (A)
Arc force current range (A)
AC frequency (Hz)
Initial current range (A)
Peak current range (A)
Base current range (A)
Crater current range (A)
DC pulse frequency range (Hz)
DC pulse duration ratio range (%)
AC frequency range (Hz)
Positive and negative half-wave time ratio
(%)
AC pulse frequency range (Hz)
AC pulse duration ratio range (%)
Upslope time (s)
Downslope time (s)
Pre-flow time (s)
Post-flow time (s)
Spot welding time (s)
Arc ignition mode
5. INSTALLATION AND OPERATION.
Welding should be carried out in dry environment with its humidity not greater than 90%.
The temperature of the working environment should be between -10
Avoid welding in the open air unless sheltered from sunlight and rain. Keep it dry anytime and do not place it on wet ground or in puddles.
Avoid welding in dusty area or environment with corrosive chemical gas.
Gas shielded arc welding should be operated in environment without strong wind.
Ensure good ventilation: This welder can create powerful welding current that has strict cooling requirements that cannot be met with
natural ventilation. Therefore the built-in fan is very important in enabling the machine to work stable with effective cooling. The operator
should make sure that the louvers be uncovered and unblocked. The minimum distance between the machine and nearby objects should
be 30cm. Good ventilation is of critical importance to the normal performance and lifespan of the machine.
Smart Tig 310 P ACDC
Common parameter
Parameters in MMA (DC, AC)
Parameters in TIG (DC, DC pulsed, AC, AC pulsed)
Please install the machine strictly following the steps in this section.
Electric shock can cause personal injury or even can kill.
Working environment of machine
3-phase; 400V AC, 50/60Hz
9
8.4
40
TIG: 315/22.6; MMA: 250/30
60
50
F
Forced air cooling
IP23
590×375×380
33
DC: 10~250; AC: 20~250
DC: 10~300; AC: 20~300
0~100
50
DC: 10~320; AC: 20~250
DC: 10~320; AC: 30~320
DC: 10~320; AC: 30~320
DC: 10~320; AC: 20~250
0.5~200
10~90
20~70
10~60
0.5~5.0
10~90
0~60
0~60
0~15.0
0~20.0
0.0~8.9
Contact arc ignition, HF arc ignition
℃ to 40℃ .