Standard 4T mode:
⑤ Push the torch trigger: arc is ignited and current
reaches the initial value.
⑥ Release it: current rises gradually.
⑦ Push it again: current drops to pilot arc current
value.
⑧ Release it: arc stops.
Double operation 4T mode:
⑤ Push the torch trigger: arc is ignited and current
reaches the initial value. The torch trigger can be
released at any time.
⑥ Release it: current rises gradually. The torch trigger
can be released at any time.
⑦ Push it again: current drops to pilot arc current
value. The torch trigger can be released at any time.
⑧ Release it: arc stops.
Cycle single operation mode without initial current:
⑤ Push the torch trigger: arc is ignited and current
rises gradually.
⑥ Release it: current drops to pilot arc current value.
then turn to ②.
⑦ Push it again: current rises gradually again, and
⑧ If push the torch trigger and release it at once, arc
will stop.
Cycle single operation mode with initial current:
⑤ Push the torch trigger: arc is ignited and current
reaches the initial value.
⑥ Release it: current rises gradually.
value, and turn to ②.
⑦ Push it again: current drops to pilot arc current
⑧ If release the torch trigger and push it at once, arc
will stop.
Inner timing operation mode:
⑤ Push the torch trigger: arc is ignited and current
rises gradually.
1s, it will turn to ③.
⑥ If release it within 1s, arc will stop; if release it after
⑦ Push it again: current drops gradually, and arc
stops. The torch trigger can be released at any time.
current will gradually rise again, and then turn to ③.
⑧ If push the torch trigger again before arc stops, the
Smart Tig 310 P ACDC
1s
Pág. 50