Elvox EC25 Manuales Instrucciones página 12

Ficha de control sin receptor radio
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
4.2. DELETION OF ALL THE RADIO CODES
This procedure is used to delete all the saved codes. Deleting a single code is not permitted.
To delete ALL the saved radio codes, proceed as follows:
- Press the RESET button, on the top right of the card. An audible warning indicates the deletion phase has started.
- Press the MEMO button, and keep it pressed until the green LED (MEMO) comes on
- Let it go and press the MEMO button again until the green LED (MEMO) lights up again and blinks.
- Let it go once more and press the MEMO button again until the green LED blinks faster. At this point the radio codes are all deleted and the green
LED (MEMO) goes out.
To stop the deletion procedure, press the RESET button before the end of the process.
5. ADJUSTMENTS ON THE CARD
5.1. DIP SWITCH
There are 6 Dip-Switches that adjust the card's basic operation. The values of the dip-switches are read when the card is powered up, or on pressing
the card's RESET button.
Dip 1
OFF
OFF
ON
ON
Note: with dip 4 in ON and Dip 5 in ON in opening mode, it accepts only the command "open". With the automation completely open or in closing
mode, it accepts the command STOP.
Dip 2
OFF
ON
OFF
ON
Dip 3
OFF
ON
Dip 4
OFF
ON
Dip 5
OFF
ON
Dip 6
OFF
ON
Fig. 13
% opening
85
70
50
20
Condominium function
Funct. Normal as for dip 5
Until complete opening it only accepts the open command, on closing a
new command reverses the direction of travel
Open / Stop / Close
One impulse Opens, one Closes
One impulse Opens, one Stops and one Closes
No. 2 flashes before opening and No.3 flashes before closing
Starts the movement with the first flash of the flasher
- 12 -
Slowdown
Null
Minimum
Medium
Maximum
Automatic closing
not inserted
Inserted
Cancel flashing

Publicidad

Tabla de contenido
loading

Tabla de contenido