5.2. OPERATING PARAMETER SETTING
Parameter
Start Slowdown
Automatic closing
Condominium Function
Open/Stop/Close
Flashing
5.3. POTENTIOMETERS
The three potentiometers set the minimum speed, maximum speed and the electronic clutch of the card (Default values). The values are read when the
card is powered, or by pressing the card's RESET button
Potentiometer
CLUTCH.
SLOW. V.
MAX. V.
The potentiometers are adjusted in the laboratory in the testing phase:
CLUTCH.
+
Minimum sensitivity to obstacles
(maximum power)
NOTE: The new dip-switch and trimmer values are read by pressing the card RESET push-button.
6. CONTROL UNIT TERMINAL DESCRIPTION
Supply voltage
12Vc.a.
2° channel
M
Motor supply
voltage
Fuses:
F1: 2A
Fuses for accessory protection
F2: 15A
Fuses for battery protection
F3: 15A
Fuses for net protection
CAUTION: If one of the normally closed (N/C) inputs is not used, insert a jumper between COM 1 and the terminal.
DIP 1
DIP 2
OFF
OFF
Greater sensitivity to obstacles
Supply voltage
PLUG
12Vc.c.
Connection
950B
2A
15A
15A
-
+
(-)
(+)
Accessory
Motor
(+)
(-)
supply voltage
encoder
17 Vc.c.
1 W
DIP 3
DIP 4
DIP 5
DIP 6
ON
ON
OFF
OFF
Minimum Adjustment (-)
Minimum slowdown speed
Minimum travel speed
SLOW.V.
+
Medium slowdown speed
LED
Parameter
net supply
adjustment
voltage
potentiometers
Signs
Controls - safety
- 13 -
Maximum Adjustment (+)
Less sensitivity to obstacles
Maximum slowdown speed
Maximum travel speed
Maximum travel speed
Led RESET
Push-buttons for storing the
travel and the radiocommands
Led MEMO
Dip Switch for parameter
setting
(-)
(+)
Radio receiver
connection
PC
connection
MAX. V.
+