7. Adjust the position of the hood by means of the
adjustment screws.
8.
Electrical connection
WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel
before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN ELECTRICAL
JUNCTION BOX WITH 3 WIRES, ONE OF WHICH
(GREEN/YELLOW) SERVES TO GROUND THE
APPLIANCE. TO PROTECT YOU AGAINST
ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE
MUST BE CONNECTED TO THE GROUNDING WIRE
IN YOUR HOME ELECTRICAL SYSTEM, AND IT
MUST UNDER NO CIRCUMSTANCES BE CUT OR
REMOVED.
Failure to do so can result in death or electrical
shock.
Remove the Junction box cover and install the conduit
connector (cULus listed) in junction box.
9.
Run 3 wires; black, white and green ,according to the
National Electrical Code and local codes and
ordinances, in 1/2" conduit from service panel to
junction box.
10.
Connect black wire from service panel to black or red in
junction box, white to white and green to green-yellow.
Close and secure junction box cover.
11. Fix the junction box to the support bracket on the ceiling
with 2 screws.
Important! Replacement of the interconnection cable
must be carried out by the authorised after-sales
technical service.