instruCtions for use

fluid dispensing

1 . . Unscrew .the .cap .from .the .fluid .transfer .
bottle, .and .fill .to .desired .level .with .clean .
fluid .
2 . . Reinstall .the .cap .onto .the .bottle .and .hang .
the .assembly .in .a .safe, .secure .location .
within .reach .of .the .application .
3 . . Close .the .ball .valve .located .on .the .fluid .hose .
assembly .extending .from .the .bottom .of .the .
bottle .
4 . . Connect .the .fluid .dispensing .wand .or .other .
accessory .to .the .quick-change .coupler .on .
the .end .of .the .fluid .hose .assembly . .Ensure .
the .coupler .sleeve .snaps .forward .to .lock .the .
connection .
5 . . Connect .a .Mityvac .hand .pressure .pump .w/ .
pressure .gauge .to .the .inlet .hose .extending .
from .the .side .of .the .fluid .transfer .bottle .
6 . . While .observing .the .gauge, .operate .the .
pump .to .build .pressure .in .the .fluid .transfer .
bottle .to .the .desired .level . .Do .not .exceed .
1 .4 .bar .(20 .psi) .pressure .
7 . . Insert .the .fluid .wand .into .the .reservoir .you .
wish .to .fill .or .top-off, .and .open .the .ball .valve .
to .allow .the .flow .of .fluid .
.
note: .Continual .operation .of .the .pump .is .
not .required .to .maintain .fluid .flow . .Fluid .will .
continue .to .flow .as .long .as .there .is .pres-
Hand .pump .
(sold .separately)
TYPICAL .DISPENSING/ .
EVACUATION .APPLICATION
Form 801689
sure .in .the .reservoir .and .the .shutoff .valve .is .
open .
8 . . Once .the .proper .amount .of .fluid .has .been .
dispensed, .close .the .shutoff .valve .and .
release .the .pressure .in .the .system .by .acti-
vating .the .pressure .relief .lever .on .the .hand .
pump .
9 . . Depending .on .the .type .of .fluid .and .future .
intended .use, .you .may .store .the .remaining .
fluid .in .the .reservoir . .Otherwise .empty .the .
bottle .assembly, .clean .it .with .denatured .
alcohol .or .a .common .household .cleaner, .
and .store .it .properly .
fluid evacuation
1 . . Hang .the .fluid .transfer .bottle .assembly .in .
a .safe, .secure .location .within .reach .of .the .
application .
2 . . Close .the .ball .the .valve .located .on .the .fluid .
hose .assembly .extending .from .the .bottom .
of .the .fluid .transfer .bottle .
3 . . Connect .the .fluid .dispensing .wand .or .other .
accessory .to .the .quick-change .coupler .on .
the .end .of .the .fluid .hose .assembly . .Ensure .
the .coupler .sleeve .snaps .forward .to .lock .the .
connection .
4 . . Connect .a .Mityvac .hand .vacuum .pump .to .
the .inlet .hose .extending .from .the .side .of .the .
fluid .transfer .bottle .
5 . . Operate .the .pump .to .build .vacuum .in .the .
bottle .
Fluid .dispensing .wand
Brake .master .cylinder
Page Number - 5