Información
Datos
Instalación
de Seguridad
Nominales
Mecánica
Disipación de calor
Durante el arranque .......................................................................................................................................... 4,5 vatios por amperio
Durante la marcha
D3-1x-0023-B a D3-1x-0053-B ......................................................................................................................... ≤ 39 vatios aprox
D3-1x-0076-B a D3-1x-0105-B ......................................................................................................................... ≤ 51 vatios aprox
D3-1x-0145-B a D3-1x-0220-B ....................................................................................................................... ≤ 120 vatios aprox
D3-1x-0255-B a D3-1x-0500-B ........................................................................................................................ ≤ 140 vatios aprox
D3-1x-0700-B a D3-1x-1000-B ........................................................................................................................ ≤ 357 vatios aprox
D3-1x-0255-N a D3-1x-0930-N ....................................................................................................... 4.5 vatios por amperio aprox
D3-16-1200-N a D3-16-1600-N ...................................................................................................... 4.5 vatios por amperio aprox
Ruido de ventilador
D3-1x-0076-B a D3-1x-0220-B (excepto D3-1x-0170-B) ............................................................................................................... 32 db
D3-1x-0255-B a D3-1x-1000-B ...................................................................................................................................................... 49 db
D3-1x-0255-N a D3-1x-0430-N ...................................................................................................................................................... 49 db
D3-1x-0650-N a D3-1x-0930-N .................................................................................................................................................... 56 db
D3-16-1200-N a D3-16-1600-N .................................................................................................................................................... 58 db
Certificaciones
UL / C-UL .................................................................................................................................................................................. UL 508
D3-1x-0023-B a D3-1x-0105-B ............................................................................................... IP20 & NEMA1, UL Indoor Type 1
D3-1x-0145-B a D3-1x-0220-B ......................................................................................................... IP00, UL Indoor Open Type
D3-1x-0700-B a D3-1x-1000-B ......................................................................................................... IP00, UL Indoor Open Type
D3-1x-0255-N a D3-16-1600-N .......................................................................................................... IP00, UL Indoor Open Type
CE
.............................................................................................................................................................................. IEC 60947-4-2
C
................................................................................................................................................................................. IEC 60947-4-2
RoHS ...................................................................................................... Conforme con la Directiva de la Unión Europea 2002/95/EC
Vida útil (contactos del bypass interno)
D3-1x-0023-B a D3-1x-0105-B .......................................................................................................................... 1,000,000 operaciones
D3-1x-0145-B a D3-1x-1000-B ............................................................................................................................. 100,000 operaciones
D3-1x-0220-B a D3-1x-1000-B: Se debe comprobar el desgaste de los contactos de los interruptores del bypass interno
después del número indicado de operaciones. Puede que sea necesario una revisión periódica.
ADVERTENCIA
88
Instalación
Teclado
Puesta en
Funcionamiento Programación Diagnósticos Ejemplos
Eléctrica
y Estado
Marcha del
Arranque
Rápido
www.leroy-somer.com
Datos
Mantenimiento Opciones
de
Técnicos
aplicación
Guía del usuario del Digistart D3
Versión: E