Dmx Linking - Chauvet Professional Q-Wash 436Z-LED Guía De Referencia Rápida

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
AC Power
Power Linking
AC Plug
Replacing the
Fuse

DMX Linking

DMX Connection
Master/Slave
Connection
This product has an auto-ranging power supply that can work with an input
voltage range of 100~240 VAC, 50/60 Hz.
You can link up to 2 Q-Wash™ 436Z-LED products at 120 VAC or 6 at
230 VAC. Never exceed this number. Power linking cords can be
purchased separately.
Connection
AC Live
AC Neutral
AC Ground
1.
Disconnect this product from power.
2.
Using a Phillips #2 head screwdriver, unscrew the fuse holder cap
from the housing.
3.
Remove blown fuse and replace with a good fuse of the same type and
rating.
4.
Screw the fuse holder cap back in place and reconnect power.
The Q-Wash™ 436Z-LED will work with a DMX controller using a
regular DMX serial connection. A DMX Primer is available from
www.chauvetpro.com.
The Q-Wash™ 436Z-LED uses a regular DMX data connection for its
DMX personalities: PERSON 1, PERSON 2, PERSON 3, PERSON 4,
and PERSON 5. See the User Manual to connect and configure for DMX
operation.
The Q-Wash™ 436Z-LED uses the DMX data connection for its
Master/Slave mode. See the User Manual to connect and configure for
Master/Slave operation.
Q-Wash™ 436Z-LED QRG
Wire (U.S.)
Wire (Europe)
Black
White
Green/Yellow
Green/Yellow
3
Screw Color
Brown
Yellow/Brass
Blue
Green
Silver