Switching To Automatic Mode - Dometic TEC29 EV Instrucciones De Uso

Ocultar thumbs Ver también para TEC29 EV:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 80
Operating the generator
➤ Switch the generator to no function with the main switch (fig. 5 1, page 5).
➤ Disconnect the positive terminal of the supply battery.
➤ Take the dipstick (fig. 5 2, page 5) out of the filler neck (fig. 5 3, page 5).
➤ Clean the dipstick (fig. 5 2, page 5) with a cloth.
➤ Put the dipstick (fig. 5 2, page 5) back into the filler neck (fig. 5 3, page 5).
➤ Take the dipstick (fig. 5 2, page 5) out of the filler neck.
➤ Check that the oil level is between the notch (maximum filling level) and the tip of
the dipstick (fig. 5 4, page 5).
If not, top up with more oil.
➤ Put the dipstick (fig. 5 2, page 5) back into the filler neck (fig. 5 3, page 5).
➤ Check that the oil level is not above the maximum level.
➤ Connect the generator to the positive terminal of the supply battery.
➤ Switch the generator to standby with the main switch (fig. 5 1, page 5).
➤ Close the generator front door.
8.8

Switching to automatic mode

You can only switch to automatic mode:
• if it was configured when the generator was installed
• if the vehicle is stationary and the ignition is switched off
• if the automatic mode switch (if available) is switched on
In automatic mode, the generator switches on automatically and charges the battery
if the voltage of the connected battery is too low.
The generator switches off automatically once the battery has been fully charged.
To switch on the automatic mode:
➤ Switch on the automatic mode switch (if available).
➤ Switch the ignition off.
➤ Switch the remote control on by pressing the on/off switch.
✔ The display shows:
22
AUTO?
TEC29 EV
EN

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido