Drill holes using carbide
tipped masonry drill bit per
ANSI B212.15-1994 (R2000)
STANDARD
Minimum Floor Thick-
ness
Anchor
Minimum Concrete
Strength
Minimum Anchor Em-
bedment
Minimum Distance to
Concrete Edge, Crack,
Expansion Joint, Aban-
danoned Anchor Hole
*The supplied concrete fasteners meet the criteria of the American National Standard
"Automotive Lifts - Safety Requirements for Construction, Testing, and Validation" ANSI/ALI ALCTV-2011, and the lift
owner is responsible for all charges related to any additional anchoring requirements as specified by local codes.
Clean hole.
CONCRETE AND ANCHORING REQUIREMENTS
ANSI/ALI ALCTV
4-1/4 INCHES
4-3/8 INCHES
Hilti Kwik Bolt III*
Hilti HIT-HY
5/8" x 4-1/4"
150MAX-SD
Adhesive; Hilti
HIT-HY 150 MAX
Adhesive; HILTI
HIT-RE 500-SD
Adhesive
3000 PSI
3000 PSI
2-3/4 INCHES
3-1/8 INCHES
4-1/2 INCHES
3-1/8 INCHES
Contact customer service for further information at: 800.445.5438
Run nut down just
below impact section
of bolt. Drive anchor
into hole until nut and washer
contact base.
IBC 2006, 2009, 2012
5 INCHES
Hilti Kwik Bolt III
5/8" x 6"
3000 PSI
3-1/8 INCHES
2-1/4 INCHES
7
Tighten nut with
Torque wrench to
60 ft.-lbs.
Fig. 12a
SEISMIC
Varies by location consult
with your structural engineer
and manufacturer's repre-
sentative.
Fig. 12b