Installing the device

6
Installing the device
!
WARNING!
Assembly and installation of the device must only be carried out by spe-
cialists. Incorrect assembly and installation can result in serious hazards
due to the escape of gas.
6.1

Selecting the installation location

When selecting the installation location, observe the following instructions:
• Consider the volume of air required for combustion (chapter "Technical data" on
page 30).
• During operation, there must be air vents with a cross-section of at least 150 cm
in the installation room.
• Make sure that minimum distances (fig. 2, page 4) are observed.
• Ensure that there are no drafts at the installation location.
6.2
Installing the device
➤ Create a cutout according to the installation drawing:
– PI80x2: fig. 3, page 4
– PI80x3: fig. 4, page 5
– PI90x3: fig. 5, page 5
– MO71x3: fig. 6, page 6
– MO9222: fig. 7, page 7
– MO9722: fig. 8, page 8
– CE-99-ZF: fig. 9, page 9
– CE99-DF: fig. 0, page 9
– KSK2007R: fig. a, page 10
➤ Affix the device to the worktop using the screws (fig. b, page 10 – fig. d,
page 12).
6.3

Connecting the device to the gas supply

!
WARNING! Beware of injury!
Only use propane or butane gas cylinders with a certified pressure
reduction valve and suitable head. Compare the pressure information
on the type plate with the pressure information on the propane or
butane gas cylinder.