SERVICE CHECKS
CONDITION
Regulated pressure creep.
Regulated pressure drop.
Fluid leakage from under
bonnet.
ACCESSORIES
1 MA-25, GA-333, GA-288 : Manometer 2.5b, 6b or 10bar.
2 S-3008 : Stainless steel adapter 1/4'' BSP female / female
3 S-3007 : Stainless steel riser tube 1/4''BSP – male/male
4 S-3006 : Tee in stainless steel 1/4'' BSP – Female
5 HGB-66 : Stainless steel reducer 1/4''x 3/8 '' BSP male/male (no retention)
S-3009 : Stainless steel coupling 1/4''BSP Male/Male

EC DECLARATION OF CONFORMITY

We, Finishing Brands, as the manufacturer of the fluid regulators HGB-509, HGB-510, HGB-609, declare under our sole
responsibility, that the equipment to which this document relates is in conformity with the following standards or other normative
documents :
EN 292-1 PARTS 1 & 2: 1991, EN 1953: 1999; and thereby conform to the requirements of; Council Directive 98/37/EC relating to
Machinery Safety Directive.
These regulators are classed as components, by the ATEX directive 94/9/EC "Equipment and Protective Systems intended for
use in Potentially Explosive Atmospheres" and are in conformity with the provisions of the directive, protection level II 2 G.
Finishing Brands reserve the right to modify equipment specification without prior notice.
SB-6-HGB-R (11/2015)
CAUSES
Improper seating of valve stem on seat.
Diaphragm leaking.
Restriction in main material line or at
valve seat inlet.
Diaphragm damaged.
Loose cap screws.
Diaphragm damaged.
7 / 7
REMEDES
Be sure that seat and ball valve are not damaged,
worm or dirty.
Replace.
Clear l'obstruction
Replace.
Screw the 6 screws at a torque 8 mN.
Replace.
Chuck McCulloch, Finishing Brands
March 18, 2014