Care And Cleaning - Everbilt EFLS10-HD Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Care and Cleaning

To clear a pump clogged with debris:
1.
Unplug the pump from electrical power.
2.
Remove the nut (3).
3.
Remove the clamp (5), O-ring (2), O-ring (4) and volute (1).
4.
Remove screws (6) fastening the diffuser (7) to the seal plate and remove the diffuser (7).
5.
Remove debris from around the impeller (8).
6.
Reassemble the pump.
Maintenance
Pump should have adequate ventilation to prevent overheating. Bearings do not require lubrication as they are permanently lubricated
from factory.
Winteri ation
z
Do not allow pump or pipes to freeze. Drain system before freezing temperatures are excepted. To drain, remove plug from discharge
tee and remove plug from bottom front of pump. All piping should be drained to below frost line.
8
7
6
5
4
3
9
Please contact 1-844-883-1872 for further assistance.
2
1
HOMEDEPOT.COM

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Efls15-hdEfls20-hd

Tabla de contenido