Installation / Operation
Protect electrical cord from sharp objects, hot surfaces, oil, and
chemicals. Avoid kinking cord. Replace or repair damaged or
worn cords immediately.
Do not handle pump or pump motor with wet hands or when
standing on wet or damp surface, or in water.
Do not use this pump in a fish pond.
Risk of electrical shock. Can burn or kill. If your
basement has water or moisture on floor, do not walk on wet
area until all power has been turned OFF. If shut-off box is in
basement, call electric company or hydro authority to shut-off
service to house, or call your local fire department for instruc-
tions. Remove pump and repair or replace. Failure to follow this
warning can result in fatal electrical shock. Oil on the pump or
in the sump may indicate motor leakage and electrical shock
hazard. Turn OFF power and check pump for oil leakage from
impeller area. Replace pump if it leaks.
NOTE: This unit is not designed for applications involving salt
water or brine! Use with salt water or brine will void warranty.
Pump water only with this pump.
INSTALLATION
1. Install pumps in sump pit with minimum diameter of 12".
Sump depth should be 18". Construct sump pit of tile, con-
crete, steel, or plastic. Check local codes for approved
materials.
2. Install pump in pit so that switch operating mechanism has
maximum possible clearance.
3. Pump should not be installed on clay, earth, or sand surfaces.
Clean sump pit of small stones and gravel which could clog
pump. Keep pump inlet screen clear.
NOTE: Do not use ordinary pipe joint compound on plastic
pipe. Pipe joint compound can attack plastics.
4. Install discharge plumbing. Use rigid plastic pipe and wrap
threads with Teflon tape or use Plasto Joint Stik
into pump hand tight +1 to 1-1⁄2 turns.
Risk of flooding. If a flexible discharge hose is
used, make sure pump is secured in sump to prevent movement.
Failure to secure pump may allow pump movement, switch
interference, and prevent pump from starting or stopping.
5. To reduce motor noise and vibrations, a short length of rub-
ber hose (1-7⁄8" I.D., e.g. radiator hose) can be connected
into discharge line near pump using suitable clamps.
6. Install an in-line check valve to prevent flow backwards
through pump when pump shuts off.
7. Power Supply: Pump is designed for 115 V., 60 Hz., opera-
tion and requires a minimum 15 amp dedicated circuit. Both
pump and switch are supplied with 3-wire cord sets with
grounding-type plugs. For automatic operation, switch plug is
inserted directly into outlet and pump plug inserts into oppo-
site end of switch plug. For manual operation, pump plug is
inserted directly into outlet.
1
Lake Chemical Co., Chicago, Illinois
a suitable electrical ground such as a grounded water pipe or
a properly grounded metallic raceway or ground wire system.
Do not cut off round ground pin.
8. If pump discharge line is exposed to outside sub-freezing
atmosphere, portion of line exposed must be installed so any
water remaining in pipe will drain to the outfall by gravity.
Failure to do this can cause water trapped in discharge to
freeze which could result in damage to pump.
9. After piping and check valve have been installed, unit is
ready for operation.
10. Check operation by filling sump with water and observing
pump operation through one complete cycle.
lead to improper operation, premature failure, and flooding.
OPERATION
pump motor with wet hands, or when standing on wet or damp
surface or in water.
1. Shaft seal depends on water for lubrication. Do not operate
pump unless it is submerged in water as seal may be dam-
aged if allowed to run dry.
2. Motor is equipped with automatic reset thermal protector. If
temperature in motor should rise unduly, switch will cut off
all power before damage can be done to motor. When motor
has cooled sufficiently, switch will reset automatically and
restart motor. If protector trips repeatedly, pump should be
removed and checked as to cause of difficulty. Low voltage,
long extension cords, clogged impeller, very low head or lift,
etc., could cause cycling.
3. Pump will not remove all water. If manually operated pump
is operating and suddenly no water comes out of discharge
. Screw pipe
1
hose, shut OFF unit immediately. Water level is probably
very low and unit has broken prime.
NOTE: For continuous operation, water depth must be at least 2"
(5 cm).
check why unit has stopped operating, disconnect power from
unit. Do not handle pump with wet hands or when standing on
wet or damp surfaces, or in water.
NOTE: No repair parts are available for these pumps.
Pump should always be electrically grounded to
Failure to make this operational check may
Risk of electric shock. Do not handle a pump or
Risk of electric shock. Before attempting to