Route Of Pipeline; Drain Pipe Connection - Beko BEVPA 090 Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

8
Install indoor unit
C
Note: Usually, the wall hole is 060mm~080mm. Avoid pre-buried power wire and hard
wall when making the hole.

8.4 Route of pipeline

1. Depending on the position of the unit, the piping may be routed sideway from the left or the
right (Fig 1), or vertically from the back (Fig 2) (depending on the pipe length of the indoor unit). In
the case of sideway routing, cut off the outlet cutting stock of the opposite side.
Fig 1

8.5 Drain pipe connection

1. Remove the mountings and pull the indoor unit pipe out of the housing.
2. Connect the connecting pipe to the indoor unit:
Aim at the pipe center, tighten the Taper nut with fingers, and then tighten the Taper nut with a
torque wrench, and the direction is shown in diagram on the right. The torque used is shown in the
following table.
C
Note: Carefully check if there is any damage of joints before installation. The joints
shall not be reused, unless after re-flaring the pipe.
34 / 220 EN
Putty
Connecting pipe
drain hose and
cables
Outlet material preparation
Split type wall mounted air-conditioner / Owner's Manual
Pipe protection ring
Fig 2
Connecting pipe
drain hose and
cables

Publicidad