8
Install indoor unit

8.7 Fixing the indoor unit

1. Hang the indoor unit on the peg board, and move the unit from left to right to ensure that the hook
is properly positioned in the peg board.
2. Push toward the lower left side and the upper right side of the unit toward the peg board, until the
hook is embedded in the slot and makes a "click" sound.

8.8 Wiring diagram

• I f your air conditioner is provided with power cable, the wiring of the indoor unit is connected in the
factory, there is no need of connection.
• I f the power cable is not provided, connection is needed in accordance with the wiring diagram.
After installation, check:
1. The screws whether have been fixed effectively, and there is no risk of loosening.
2. Connector of display board whether put in the right place and do not touch the terminal board.
3. Control box cover whether cover tightly.
Constant speed
5
3
4
2(N)
To outdoor unit
5
4
3
2(N)
To outdoor unit
36 / 220 EN
L
1(L)
To outdoor unit
1(L)
L
Lo
Split type wall mounted air-conditioner / Owner's Manual
Variable speed
S
N
S
N
To outdoor unit
Connector
If there is a connector,
connect it directly.