Install The Connection Pipe - Beko BEVPA 090 Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

9
Install outdoor unit
825 (880) × 655 × 310
900 (950) × 700 × 350
900 (950) × 795 × 330
970 (1044) × 803 × 395

9.2 Install the connection pipe

Connect the Outdoor Unit with Connecting Pipe: Aim the counter-bore of the connecting pipe at the
stop valve, and tighten the Taper nut with fingers. Then tighten the Taper nut with a torque wrench.
• W hen prolonging the piping, extra amount of refrigerant must be added so that the operation and
performance of the air conditioner will not be compromised.
Piping length
≤ 5 M
5-15 M
Note:
C
1. This table is for reference only.
2. The joints shall not be reused, unless after re-flaring the pipe.
3. After installation, check the stop valve cover whether be fixed effectively.
Split type wall mounted air-conditioner / Owner's Manual
Stop valve
Taper nut
Amount of refrigerant to be added
Not needed
CC ≤ 12000 Btu
CC ≥ 18000 Btu
540
630
535
675
Connecting
pipe
liquid side pipe
Gas side pipe
Spanner
Amount of refrigerant for the unit
16 g/m
≤ 1 kg
24 g/m
≤ 2 kg
335
350
350
409
39 / 220 EN