Establishing The Electrical Connection En - Abicor Binzel iROB Cool Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

iROB Cool
6.2.2 Establishing the electrical connection
NOTICE
• Use appropriate lifting tool with load handling devices for transport and installation of the
• Secure the robot welding power source against fold down.
• When placing the robot welding power source, make sure that connecting plugs and cables are not
2
3
1
1
Plug of the BUS connection
2
Socket of the BUS connection
3
Power supply connector
4
Plug of the power supply 400V
Fig. 5
Installation/mounting
1 Dismount the protection plate (9) at the bottom of the robot welding power source (8). Keep it for later
dismounting.
2 Introduce cable plug-in connections into the opening in the bottom plate of the robot welding power
source (8).
Personal injuries and material damage
Incorrect plug-in connections of the cables can result in personal injuries and material damage.
• The plug-in connections are marked on the cables.
• Before connecting cables, make sure that the plugs that match are joined.
• Do not use force to join plug-in connections.
3 Place the robot welding power source (8) on the iROB Cool coolant recirculator (7).
4 Establish BUS connection via the plug (1) and socket (2).
5 Establish power supply via the plug-in connection (4) or (5) and (3).
Plug (5) for MV system with 230V, plug (4) for 400 V.
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
BAL.0332.0 • 2017-08-31
iROB Pulse robot welding power source.
kinked or damaged.
4
5
5
Plug of the power supply 230V (MV)
6
M5x14 (4x) screws
7
Coolant recirculator iROB Cool
DANGER
DANGER
6 Putting into operation
6
3
2
10
7
8
Robot welding power source iROB Pulse
9
Protection plate with M4x10 (2x) screws
10 Cable binder
8
9
EN - 13