Rugby 260SG / 270SG / 280DG, Operation
4
4.1
Backlight
Settings
Temperature
compensation

Operation

General

Per default the backlight is always off.
To switch on the backlight, press the POWER button shortly.
All setup options are stored when the Rugby is turned off.
On a Rugby 260SG, the H.I. function is active per default after power on.
Refer to chapter "3.2 Setup Options" to see how the H.I. function can be
turned off.
After the Rugby has been turned on, the temperature is measured. If the temperature
changes by more than 5°C / 9°F it compensates and applies this change to the level-
ling system when grade has been entered.
The temperature compensation process is indicated by a
progress bar (a).
During this process, head rotation stops and the laser beam
is turned off.
Once completed the Rugby returns back to the grade and the head starts to rotate.
22