Adjusting Level Accuracy - Leica Rudby 260SG Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5.2
Enter adjustment
mode
X-axis accuracy
adjustment
Rugby 260SG / 270SG / 280DG, Checking Level Accuracy

Adjusting Level Accuracy

With the Rugby turned off, press and hold both the UP and DOWN buttons then
press the POWER button to put the Rugby in adjustment mode.
Wait until the hour glass disappears before
checking and changing the adjustment numbers.
Use the UP and DOWN buttons to change the number and move the beam
to the half-way point between the positions marked for the X-axis.
5 counts in the display (one button press) are equal to approximately 0.3 mm
at 30 m (0.01" at 100 ft).
Press the STAR button to accept the number in the display for the X-axis and
move to the Y-axis adjustment screen.
31

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rudby 270sgRudby 280dg

Tabla de contenido