10.4.5.

MENU MONITOR

This menu shows some technical parameters of the stove. By pressing the keys
D84 and D85):
Monitor
Exhaust T.
Stove Room T.
Air Flux
D83
10.4.6.

MENU MANUAL AUGER LOAD

If during the operation of the stove, it runs out of fuel, in order to avoid any problem during the next ignition, it
is possible to carry out a preload of pellet of the auger during a maximum time of 600 seconds when the stove
is turned off and cold and the door is closed. In order to start the load, access the submenu "manual load"
by pressing the key SET. Select the option ON and confirm with SET. The smoke extractor will start working
during the load for safety reasons. In order to interrupt the load, press the key ESC.
Before proceeding with a new ignition of the stove, do not forget to empty the burner in order to avoid a
dangerous situation (see drawing D86).
Thermostat Management
Enabled
Disabled
D87
Time and Date
11:46
Wednesday
08/04/2015
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
Monitor
Fan Speed
123ºC
Auger
23ºC
Work Time
430 cm/s
D84

10.4.7. MENU APPROACH

10.4.7.1. SUBMENU THERMOSTAT MANAGEMENT

In this submenu, it is possible to activate or deactivate the function of the
thermostat of the remote control.
If the thermostat of the remote control is activated, the operation of the stove
will depend on the temperature detected by the remote control, no matter
what its position is. It is possible to deactivate this function so that the stove
depends on the temperature of the room probe of the stove. In this way, it
detects the temperature of the room where the stove is placed. (see drawing D87)

10.4.7.2. SUBMENU STANDBY RADIO

This menu allows to turn off completely the remote control. This reduces the
battery consumption. If you press the key SET, the screen shows "enabled"
and if you press again the key SET, the remote control deactivates and turns
off. In order to activate again the remote control, press
(see drawing D88)

10.4.7.3. SUBMENU DATE AND TIME

Set up date and time It is necessary to introduce the value for each field
(hours, minutes, year, month, day) by pressing SET (see drawing D89). The
electronic card has a lithium battery that allows the autonomy of the clock to
be from 3 to 5 years.
D89
, the following screens will appear (see drawings D83,
Monitor
Ignitions
1300 rpm
Product Code
2.2 s
1630 h
D85
and twice the key
50
13
-------------
-------------
-------------
Manual Load
ON
OFF
Standby
Radio
Enable
D88
D86
ELSA AND PAULA