General Instructions; Connection To The Mains - Tecnoinox SEF 1 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Part 1
ELECTRIC SALAMANDER
The appliance referred to in this manual has been
manufactured in conformity to the following Directives:
73/23/EEC, 93/68/EEC "Low Voltage"; 89/336/
EEC, 92/31/EEC, 93/68/EEC "Electromagnetic
Compatibility".
The appliance shall be installed by a qualified tech-
nician according to the regulations and directives in force
in the country where it is installed, as well as the instruc-
tions in this manual. The appliance shall be used exclu-
sively by trained personnel and only for the purpose for
which it has been designed. The appliance should be
checked once a year by a qualified technician.
Remove the packaging form the appliance as well
as the protective plastic sheet, and, if necessary, re-
move traces of glue with a suitable solvent. To dis-
pose of the packaging, follow local directives.
The technical specifications are to be found on the
specification plate attached to the appliance's rear panel.
When installing the appliance, all the regulations
Before connecting the appliance to the mains, com-
pare the electrical set-up data on the data plate to the
characteristics of the local electrical energy supply.
The appliance is equipped with a connecting cable
to which the installer must connect a circuit breaker
which cuts off the flow of electricity in all poles; the
distance between the open contacts must be at least
3 mm. The circuit breaker must be easy to reach.
The cable must not be placed near heat sources.
The area around the cable must not have a tempera-
ture above 50° C. If the cable must ever be replaced,
consult the wiring diagram attached. The supply
cable's characteristics must be of a HO7 RN-F type,
or higher, and its minimum cross-section must be in
accordance with the following table:
MODEL
SEF 1
V 230~
SEF 2
V230~
SEF 2
V400~2N
The Manufacturer declines any responsibility for damage caused by improper or incor-
rect installation or maintenance of the appliance, or failure to observe safety regulations!
GB IE

General instructions

Connection to the mains

CABLE CROSS-SECTION
3x1,5 mm
2
3x2,5 mm
2
5x1,5 mm
2
in force shall be observed, such as:
• all applicable national laws in effect;
• all regional or local regulations, such as building
codes;
• directives and regulations of the local electrical
energy supplier;
• accident prevention regulations in effect;
• fire prevention regulations;
• applicable I.E.C. regulations.
The appliance should be installed under
an extractor fan for the removal of cooking
fumes.
If the appliance is installed near walls,
panels or kitchen furniture, etc., these must
be made of fire-proof material; if they are
not, they must be protected with fire-proof
material which insulates from heat.
Remove the lateral panel on the control side in
order to make the "M" terminal board accessible.
Disconnect the conductors of the electric supply cable
from the terminal board, loosen the cable clamp, and
replace the cable following the procedure inversely.
It is absolutely necessary to earth the appliance.
For this purpose, there is a screw marked with the
symbol
near the terminal board to which the
earthing conductor must be connected.
The appliance must also be connected to a
unipotential earthing circuit. The connection must be
made by means of the screw marked
on the bottom of the appliance.
4
Installation
SEF 1 - SEF 2
to be found