PYROCERAMIC COOK-TOPS

General Instructions

The appliance referred to in this manual has been manufactured in conformity to
the following Directives: 2006/96/CEE "Low Voltage"; 2004/108/CEE
"Electromagnetic Compatibility.
The appliance must be installed by a qualified technician according to the
regulations and directives in force in the country where it is installed, as well as
the instructions in this manual.
This appliance has been designed exclusively for cooking food.
Remove the packaging from the appliance as well as the protective plastic
sheet, and, if necessary, remove traces of glue with a suitable solvent.
To dispose of the packaging, follow local directives.
When installing the appliance, the following regulations must be
observed:
Applicable national laws in force;
Regional and/or local regulations, such as building codes;
Directives and regulations of the local electricity board;
Accident prevention regulations in force;
Fire prevention regulations;
To use the appliance correctly follow the warnings below:
The appliance must never be left unattended when it is being used!
Connection to the distribution network
Before connecting the appliance note the specifications necessary for the
installation: voltage, frequency, number of phases and power on the data plate
of the appliance.
The adhesive polyester data plate is behind the control panel "T"
fig.2.
The installer must make the connection after having installed a main switch,
which is easy to reach and disconnects every pole supplying electrical power to
the appliance. The switch supplying electrical energy to the appliance must have
a minimum distance of at least 3mm between the poles when the contacts are
open.
THE CABLE:
Must not be installed near heat sources, the ambient temperature of the
surrounding environment must not rise to over 50°C.
Must be protected by a rigid metal or plastic tube
Must at least meet H07 RN-F standards.
Must have the minimum section indicated in the table fig.1.
Part 1 - Installation
The appliance is designed for professional use and therefore should only be
used by qualified personnel.
Care must be taken when using the appliance because the cooking surfaces
are very hot.
The appliance should be installed under an extractor fan for removing
cooking fumes.
If the appliance is installed in line:
Respect a minimum distance of 80mm between the appliance and any walls
made of flammable material, partitions, kitchen furniture or nearby
equipment.
The surfaces in contact with the appliance must be covered with non-
combustible heat insulating material.
The appliance, and especially the power lead, must not be installed
anywhere near heat sources.
The temperature of the environment in which the appliance is installed must
not rise above 50°C.
Switch the appliance off in the case of a failure or malfunction.
To reach terminal board "M" fig.2, remove the control panel by loosening the
screws on the lower part of the panel. Following the indications in the wiring
diagram, connect the wires of the power cable to the terminal board. The
appliance must be connected to a good earth. There is a screw marked with the
symbol
near the terminal board where the earth conductor should be
connected. Make sure you slide the cable through the relevant hole "P" fig.2
near the terminal board, hold the cable in place until you can block it with cable
clamp "AL" fig.1. The appliance must be connected to a good earth. The
appliance must also be connected to an equipotential earth. Connect the earth
with the screw marked
have a section of 10mm
GB / IE - 1
on the rear panel of the. The equipotential wire must
2
.