10.4 Electrical connection
IMPORTANT
The machine must be connected to a system-mono phase 240V
60Hz.
Insert the power cable (G – F.7) into hole A (F. 5).
F. 8
According to the laws in force in the country of use of the machine,
the power cable must be equipped with an all-polar switch (with
minimum distance of 3 mm between contacts).
• The all-polar switch must be suitable to the machine supply
voltage and able to monitor all voltage polarities.
• Check that the size of the cables is suitable for the machine's
absorption.
The connection point (socket or all-polar switch) must be located
in an easily accessible place for the user to be able to disconnect
the machine from the power supply line, if necessary.
Connect the cable (G - F. 7) to the power supply line.
10.5 Serial port connection
By means of the serial port RS 232 the machine may be connected to a
Personal Computer or devices supplied to the AUTHORIZED CUSTO-
MER SERVICE CENTRES for programming operations (L - F. 9).
L
F. 9
11 - FIRST START-UP
OF THE MACHINE
Check that the removable parts (15,16 and 18) are present and that
the doors (11 and 20) are closed.
Otherwise, the message indicating the part out of place will ap-
pear on the display when the machine is turned on.
- Turn on the machine by means of the relevant switch (21);
- Open the capsule insertion box (6 and 8).
- Insert the capsule in the relevant seat as shown in figure F. 11
- Place the dispenser (22) so that a suitable height can be obtai-
ned for the containers used (Pr. 8.4).
- Place a container below the dispenser.
- Press the button corresponding to the type of beverage chosen.
IMPORTANT
Even though all the buttons have been already programmed to
standard values, it is necessary to check that the quantity of the
beverage dispensed corresponds to the one chosen. Otherwise
the dispensing buttons must be programmed (Pr. 12.6)
12 - USE OF THE MACHINE
WARNING
It is important to have read this manual carefully before use, to
ensure sufficient knowledge of the machine.
IMPORTANT
After a long period of disuse, the previous section "First
start-up of the machine" must be read before
the machine is used.
12.1 Machine status
Depending on the power supply, the machine may be in the following
conditions:
Off and electrically insulated
- Main switch (21) set in "0" position (or machine unplugged).
- Only the settings memory is active.
On
- Main switch (21) (or machine plugged).
- All functions are active and the display is on.
•
9
•