Parameter description
Alarm hysteresis
Heating element start-up interval (Anti-
Legionella)
Anti-Legionella function set
Duration of Anti-Legionella function
Solar thermal input enabling
(Digital 1)
Type of solar thermal input contact
High/low pressure end compressor protection
Photovoltaic input enabling (Digital 2)
Type of photovoltaic input contact (Digital 2)
Number of digital input alarms per equipment
block
Time for digital input alarm counter reset
Buzzer enabling
Switching on time for Monday
Switching on time for Tuesday
Switching on time for Wednesday
Switching on time for Thursday
Switching on time for Friday
Switching on time for Saturday
Switching on time for Sunday
Time for first switch on timeslot
Time for first switch off timeslot
Time according to timeslot switch on
Time according to timeslot switch off
Installation and user manual
Code
U.M.
Min
Max
A11
min
0.1
30.0
H0
days
0
99
H1
°C/°F
10.0
199.0
H3
min
0
240
i0
----
0
2
i1
----
0
1
i2
min
0
120
i3
----
0
1
i4
----
0
1
i8
----
0
15
i9
min
1
999
u9
----
0
1
Hd1
----
1
2
Hd2
----
1
2
Hd3
----
1
2
Hd4
----
1
2
Hd5
----
1
2
Hd6
----
1
2
Hd7
----
1
2
HOn1
----
00:00
23.59
HOF1
----
00:00
23.59
HOn2
----
00:00
23.59
HOF2
----
00:00
23.59
Default Notes
2.0
30
60.0
2
0 = Input disabled
2
1 = Pressure input
2 = Digital 1 input
0 = Active if contact is
closed
0
1 = Active if contact is open
0
0 = Input disabled
1
1 = Input enabled
0 = Active if contact closed
0
1 = Active if contact open
0
240
0 = Buzzer disabled
1
1 = Buzzer enabled
1 = HOn1-HOF1
1
2 = HOn2-HOF2
1 = HOn1-HOF1
1
2 = HOn2-HOF2
1 = HOn1-HOF1
1
2 = HOn2-HOF2
1 = HOn1-HOF1
1
2 = HOn2-HOF2
1 = HOn1-HOF1
1
2 = HOn2-HOF2
1 = HOn1-HOF1
2
2 = HOn2-HOF2
1 = HOn1-HOF1
2
2 = HOn2-HOF2
--:--
--:-- = Function excluded
--:--
--:-- = Function excluded
--:--
--:-- = Function excluded
--:--
--:-- = Function excluded