TROUBLESHOOTING
F A U L T
Unit does not
No power to machine.
operate
Unit not switched on.
Compressor will
Unit needs 5 minutes before restart
not start
Overload preventing start up
Blower wheel
Obstructed blower.
not turning
Unit operating,
Not enough time to dry.
but room not dry
Poor air movement in room.
Excessive moist air infiltration.
Unit
Room temperature too low
continuously in
defrost mode
Pump does not
Stuck float valve
function
Unit collects too
Room air is dry.
little water
Room temperature is too low.
Airflow through unit is restricted
If the problem you are experiencing is not listed here, call your local distributor or contact the Dri-Eaz Service
Department toll-free at 800-932-3030.
SPECIFICATIONS
Model
Evolution LGR F292-A
Type
LGR
Refrigerant
R-410A
Use weight
92 lbs. | 42 kg
Power
5 amps, 115 volts
Water removal AHAM
70 pts. | 33 liters / day
(80°F/60% RH)
Max process air
160 CFM | 272 CMH
Operating Range
33–100°F | 1–33°C
Air filter
3M HAF filter (part no. F372)
Power cord
25 ft. | 7.6 m
Dimensions
33.5 × 20.7 × 20.7 in.
(H × D × W)
85 × 52.5 × 52.5 cm
Construction
Rotomolded polyethylene housing
ETL certified to UL 474 and CSA
Safety
22.2 no. 92
Specifications are subject to change without notice. Some
values may be approximate.
Warranty information is available at www.dri-eaz.com.
07-01480C 2010-01
C A U S E
S O L U T I O N
Plug in unit; check power at outlet and at base of unit.
Switch unit on.
Switch off unit, wait 5 minutes before starting.Reduce
room temperature to 90°F (32°C) or less.
Remove duct ring and grill.
Remove obstruction.
Replace duct ring and grill.
Allow more time for drying.
Increase air movement with air movers.
Reduce infiltration.
Increase room temperature.
Clean float valve shaft.
Check humidity with hygrometer.
Increase room temperature.
Check filter and coils; clean as necessary.