M
AINTENANCE
Before each use
DriTec Pro 150
• Check and remove any air obstructions in the inlet/outlets.
DriTec Pro 150C
• Check and remove any air obstructions in the inlet/outlets.
• Check the drainage hose for obstructions or kinks.
After each use
DriTec Pro 150
• Inspect the filter, change it if an accumulation of dust and debris is present.
Dri-Eaz does not recommend washing and reusing filters.
• Check filter holder, clean if visually dirty.
• Purge pump completely
DriTec Pro 150C
• Inspect the filter. Change the filter if it has an accumulation of dust and debris.
Dri-Eaz does not recommend washing and reusing filters.
• Check filter holder, clean if visually dirty.
• Purge the pump.
• Empty the drain hose.
Filters
• Change filters a minimum of every 2 months; change more often when dirt and debris are visible, or when working on
jobs with high amounts of particulate in the air.
T
ROUBLESHOOTING
For any problems not listed below, call your local distributor or contact our Service Department toll free at 888-867-3235.
PROBLEM
Unit does not operate
Red light flashing rapidly, unit
will not operate
Red light flashing slowly, unit
will not operate (150C)
S
PECIFICATIONS
MODEL
TYPE
HEIGHT
WIDTH
DEPTH
USE WEIGHT
WATER REMOVAL MAX
WATER REMOVAL
OPERATING RANGE
PROCESS AIRFLOW
REACTIVATION AIRFLOW
DUCT RING SIZE
HOUR METER
POWER
CORD LENGTH
07-01504B Copyright 2005 Dri-Eaz Products, Inc.
POSSIBLE CAUSE
•
No power to machine
•
Switch not turned on
•
Excess temperature thermostat tripped,
turning the unit off
•
Excessive room temperature tripped the
thermostat
•
Water drain blocked
O 150C
DRITEC PRO 150
DESICCANT
14.2" (35.6 mm)
10" (25.4 mm)
17.2 " (43.7 mm)
28.7 LB (13KG)
32 PINTS/DAY (15 L)
68
°F/60% RH 27.5 PINTS/DAY
0 to 100°F (-18 to 38°C)
88 CFM (150 CMH)
150 CFM (25 CMH)
4 " (10 CM)
YES
115 V, 8.7 AMPS
10 FT (3.2M)
•
Plug in machine, check power supply
•
Press start/stop button
•
Check the filter for an airflow obstruction, and
remove if found
•
Wait until the room temperature cools below 77
(25°C)
•
Clear blockage, check the pump function
O 150C
DRITEC PRO 150C
DESICCANT
22" (55.9 mm)
10" (25.4 mm)
17.2 " (43.7 mm)
44 LB (20KG)
23 PINTS/DAY (11L)
68°F/60% RH 19 PINTS/DAY
32°F to 77°F (0 to 25 °C)
88 CFM (150 CMH)
4 " (10 CM)
YES
115 V, 8.7 AMPS
10 FT (3.2M)
SSSOLUTION