Amprobe ALC-110 Manual Del Usuario página 20

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

AC Current
Range
15 to 40 Hz
[1]
6 mA
±(5.0%+5D) ±(2.0%+5D) ±(1.0%+5D) ±(2.0%+5D)
60 mA
±(5.0%+5D) ±(2.0%+5D) ±(1.0%+5D) ±(2.0%+5D)
600 mA ±(5.0%+5D) ±(2.0%+5D) ±(1.0%+5D) ±(2.0%+5D)
6 A
60 A
Minimum Reading is 0.010 mA
[1]
Frequency response is 60 Hz to 10 kHz.
[2]
When frequency > 1 kHz, add 0.5% to accuracy.
Minimum Resolution: 0.001 mA
Low Pass Filter (50–60 Hz Filter)
Range
[1]
6 mA
60 mA
600 mA
6 A
60 A
Minimum Reading is 0.010 mA
[1]
Minimum Resolution: 0.001 mA
Cut-off frequency: 200 Hz
Appliance Filter (acc. IEC/EN 61557-16)
Range
[1]
6 mA
60 mA
600 mA
6 A
60 A
Minimum Reading is 0.010 mA
[1]
Minimum Resolution: 0.001 mA
Cut-off frequency: 1 kHz
40 to 50 Hz
-
±(2.0%+5D) ±(1.0%+5D) ±(2.0%+5D)
-
±(2.0%+5D) ±(1.0%+5D) ±(2.0%+5D)
50 to 60 Hz
±(1.0%+5D)
±(1.0%+5D)
±(1.0%+5D)
±(1.0%+5D)
±(1.0%+5D)
Accuracy
50 to 60 Hz
Accuracy
50 to 60 Hz
±(1.0%+5D)
±(1.0%+5D)
±(1.0%+5D)
±(1.0%+5D)
±(1.0%+5D)
Accuracy
16
60 to 1 kHz
60 to 200 Hz
±(2.5%+5D)
±(2.5%+5D)
±(2.5%+5D)
±(2.5%+5D)
±(2.5%+5D)
[2]
[2]
[2]