Fireplace Installation
Dimensions without trim are 26
¼ inch (663 mm) wide x 22 ⅞
inch (580 mm) high x 8 ¾ inch
(222 mm) deep. The fireplace
does not require any additional
venting (Figure 3).
Fireplace Insert
Installation
Install the fireplace assembly
into the mantel (refer to mantel
assembly instructions).
! NOTE 1: A 15 Amp, 120
Volt circuit is required. A
dedicated circuit is preferred
but not essential in all cases.
A dedicated circuit will be
required if after installation the
circuit breaker trips or fuse
blows on a regular basis when
the heater is operating.
Additional appliances
on the same circuit may
exceed the current rating of
the circuit breaker.
! IMPORTANT: If not using
a Dimplex mantel, the
fireplace must be installed
in an enclosure with
the following MINIMUM
dimensions (Figure 4).
New Wall Construction
1.
select a suitable location that
is not susceptible to moisture
and is away from drapes,
furniture and high traffic.
2.
Place the fireplace in the
desired location to see how it
will look in the room.
3.
mark the desired location on
the floor.
4.
Use studs to frame an
opening of 26 ¾ inch (679
mm) wide x 23 ⅛ inch (587
mm) high x 9 inch (229 mm)
deep.
Option #1: The power cord can
be run from behind the Trim
and along the wall to an outlet
near the fireplace.
Figure 4
9"
(229 mm)
23 ⅛"
(587 mm)
26 ¾"
(679 mm)
9