Preparing For Winter; Maintenance; Technical Data - Vetus FTANK42 Instrucciones De Instalación

Tanques de combustible fijos
Ocultar thumbs Ver también para FTANK42:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19

3 Preparing for winter

It is advisable to fill the fuel tank with fuel completely during the
winter period in order to prevent condensation. Water droplets
in fuel are the ideal transporters of dirt and rust through narrow
pipes. A full fuel tank prevents the growth of bacteria in the tank.

4 Maintenance

Regularly check the air relief nipple and clean the sieve in the nip-
ple if necessary.
Every year, check the hoses and hose connections for possible
leakage and fit new hoses and/or hose clamps as necessary. Also
check the tank for damage caused by chaffing. Replace a dam-
aged tank immediately.

5 Technical Data

Type
:
FTANK42
FTANK61 FTANK88 FTANK110
Capacity :
42
61
9.2
13.4
11.1
16.1
Weight
:
3.0
4.0
6.6
8.8
Max. pressure:
Material
:
*) The values stated in the Table are nominal values for capacity and weight. Slight deviation is possible.
10
040104.08
FTANK137 FTANK170 FTANK215 FTANK335 FTANK390
88
110
137
19.4
24.2
30.1
23.2
29
36.2
6.7
7.5
9.25
14.8
16.5
20.4
30 kPa (0.3 bar, 4.4 psi)
Polyethene, colour : natural
170
215
335
37.4
47.3
73.7
44.9
56.8
88.5
11.4
13.6
25.8
25.1
30
56.9
vetus® Rigid fuel tanks 42 - 390 litres
390
litres *)
85.8
Imp. Gallon *)
103
US Gallon *)
26.6
kg *)
58.6
lbs *)

Publicidad

Tabla de contenido
loading

Tabla de contenido