The hammam function remains available.
■ When the number indicated (Sasha: >60; Sasha mi: >30)
lights up, it signifies that it is necessary to carry out a scale re-
moval cycle (in Sasha models the number of hamman sessions is
equal to or greater than 60, while they are equal to or greater than
30 for Sasha mi).
It is not possible to activate the hammam function, you must carry
out a scale removal cycle.
■ The number of hammam sessions is indicated as follows.
This number (which may vary in relation to the model) is reset once
the water softening cycle has been performed.
■ The "water pitcher" symbol lights up when the scale removal
cycle is under way.
■ At the end of the cycle, the emptying and cleaning of the
steam generator begins, during which time, the symbol flashes;
when it goes out, the cycle can be considered finished.
WARNING SIGNALS
The symbols below, when lit up, indicate the presence of malfunc-
tions or warning conditions.
Possible causes
■ This symbol lights up when the respective keypad button is
pressed; all functions under way are interrupted (except the wa-
ter softening and sound systems, if the latter is installed).
- To deactivate the warning, press the button on the keypad once
again.
Possible causes
■ The safety thermostat may have intervened.
- Wait a few minutes and see whether the signal disappears; if this
fails to happen, switch off the main switch and switch it on once
again, and then re-start the programme.
If the problem persists, contact an authorized Jacuzzi® service centre.
Possible causes
■ The light control system may be faulty.
- Contact an authorized Jacuzzi® service centre.
Possible causes
■ The management software fails to interface.
- Try turning off and then turning on the main switch and then try to
re-start the programme: if the problem persists, contact a Jacuzzi®
Service Centre.
(red light) Possible causes
■ The temperature probe may be faulty.
- Try turning off and then turning on the main switch and then try to
re-start the programme: if the problem persists, contact a Jacuzzi®
Service Centre.
(yellow light) Possible causes
■ The door may be open or the steam generator may be damaged.
- In Sasha mi models the function is interrupted and an alarm sig-
nals; in Sasha models the door must be shut within 10 minutes after
engaging the function (after this time the function is deactivated).
If the problem persists, contact an authorized Jacuzzi® service centre.
35