2. INSTALLATION
CAUTION - The product must only be installed by qualifi ed servicing and/or installation
personnel.
CAUTION - The electrical system must comply with the current regulations in the
country where the product is installed.
CAUTION - Always disconnect the power supply before opening the container. Ensure
that a good earthing system is available and connect it to the appropriate
terminals.
2.1 PREPARATION
Before installing the device, prepare the tools required for securing it to the wall and to
make the electrical connections. The following are also required:
1. expansion wall plugs dia. 6 mm
2. Skintop type PG16 cable clamps
3. a multipole switch with a minimum contact opening of 3 mm
4. an emergency pushbutton
5. approved cables for external use with minimum cross-section of 0.75 and 1.5
mm²
2.2 ASSEMBLY
It is not necessary to drill any holes to fi t the device.
1. Secure the device at a minimum height of 30 cm, using the securing holes in the
plastic container.
2. Insert the connecting cables, through the holes in the bottom of the container and
the cable clamps indicated.
3. Fit a multipole switch upstream of the device.
4. Fit an emergency pushbutton in a position where the automation system can be
seen and so that the power supply to the system can be completely cut-off.
5. Use 1.5 mm² section cables for the motor power supply and 0.75 mm² section
cables for 24 VDC devices.
6. The device is not fi tted with peak capacitors; use the ones supplied with the
operators, or order the capacitors separately as indicated in the operator's
instructions.
2.3 ELECTRICAL CONNECTIONS
CAUTION - Make sure that the mains power supply is turned OFF before making the
connections.
CAUTION - Do not use intercom or telephone cables.
Make the electrical connections as indicated in the diagram alongside.
N.B. In accordance with the current standards, tie the connecting cables for
the different commands separately (terminals 1-11) from the power cables
(terminals 12-19).
N.B. If the terminal safety contacts 2 and 4 (stop input) and terminals 2 and 5 (photocell
input) are not used, jumpers must be fi tted.
The function of terminal input 6 depends on the setting of the dip-switches or the
logic selected and switches from N.O to N.C.
M1
1
+ 24 V
- 24 V
Common
2
Start
3
Stop
4
Photocells
5
Opening safety device
6
(DIP SWITCH 8 = ON)
Electric lock
7
Electric lock
8
-
3 W max. warning light
9
+
10
-
11
Flashing beacon
M2
Common
12
Opening
Motor 1 -
M
13
Closing
Closing delay
14
Capacitor
Common
15
Opening
Motor 2 -
M
16
Closing
Opening delay
17
Capacitor
18
Neutral
Phase 230 V
19
K4
Device earth connection
With N.O. =
Pedestrian start
(DIP SWITCH 8 = OFF)
LED
Connect motor earth to the device earth
connection
Flashing light 230 V
Important:
with this connection
the fl ashing light does not work.
Protect with differential switch 6 A
overload 30 mA