AUTOMATIC MODE. If you select this operating mode, when a pulse is given, opening
is commanded until the work time expires, the gate remains open for the selected pause
time and it then closes automatically.
• If a pulse is sent during opening, the control system ignores it and the gate continues
to open.
• If a pulse is sent or the photocells are obscured during closing, the direction is inverted
(the gate re-opens).
• During the pause stage and when the photocells are obscured, the device will remain
in pause until the photocells are cleared.
SEMIAUTOMATIC MODE WITH STOP. If you select this operating mode when the
gate is closed, when a start pulse is given, the gates open until the set work time
expires. If another start pulse is given during opening, the gates stop immediately until
another start pulse is given: this closes the automation. A start pulse sent during closing
re-opens the gates.
SUPER AUTOMATIC MODE. When you select this type of operating and a start pulse is
given, the gate opens as far as the limit switch and stays open for the pre-set pause time and
then closes automatically.
A start pulse given during any stage reverses the direction: you can close the gate with a com-
mand.
• A pulse given during the pause triggers pre-fl ashing and subsequent closing of the gate.
DIP-SWITCHES 4 and 5 (GATE CLOSING DELAY) - These SWITCHES are used to
adjust the gate closing delay for motor 1 (delayed closing), compared to the start up of
motor 2 (immediate). It can be set at 0, 3, 9 or 16 seconds.
DIP-SWITCH 6 (PRE-FLASHING) - This SWITCH is used to enable or disable pre-
fl ashing. It is possible for both the opening and closing stages. If the function is enabled,
before the automation opens or closes, there will be a signal for 3 seconds and the
warning light and fl ashing lights will come ON before the gates move.
DIP SWITCH 7 (PAUSE PHOTOCELL) - This SWITCH is used to select the pause
photocell function when the automatic functioning mode is enabled. When the SWITCH
is in the ON position, if the photocell beam is interrupted and cleared with the automation
in pause, the device will command pre-fl ashing for 3 seconds and will then close the
gate, even if the pause time has not been concluded. When the SWITCH is in the OFF
position, the gate will only close when the set pause time expires.
DIP SWITCH 8 (PEDESTRIAN START OR OPENING SAFETY DEVICE) - This
SWITCH is used to select the type of input for terrminal 6. When the SWITCH is in the
ON position, the input functions as an opening safety device. When the SWITCH is in
the OFF position, the input is enabled for single wing functioning (motor 1).
NOTE - This selection (ON/OFF) is valid for all operating modes, except Dead Man
mode. In this case, the input is always used as the closing input function.
DIP SWITCH 9 - LEAVE IN THE FACTORY-SET POSITION (OFF).
DIP SWITCH 10 (ENABLE/DISABLE ANTI-CRUSH CONTROL) - If the device controls
TORMATIC electromechanical operator, set the dip-switch to the ON position (anti-crush
card enabled).
If the device controls TORMATIC hydraulic operators, set the dip-switch to the OFF
position.

4. OPERATING CONTROL

After selecting the operating mode and times, check the external devices connected to
the card and check the state of the LED's.
4.1 CHECK THAT THE EXTERNAL DEVICES ARE OPERATING
CORRECTLY
Start input - N.O. type contact which supplies the start pulse to the automation
Stop input - N.C. safety contact which has priority in all states and functions. If the
stop input is given, the device blocks the gate immediately and it only starts up again
when the start push-button is pressed: this closes the automation. When the stop input
is given, the device ignores all the commands.
Photocell input - N.C. safety contact which is only enabled during closing. If the
photocell is obscured, the automation stops for 1 second and the gates then re-open
until the work time expires. When the gate is open and the photocells are obscured,
the photocells block gate closing.
Pedestrian start - opening/closing safety device input - The function of this input
connected to terminal 6 depends on the setting of SWITCH 8 or on the operating mode.
The following is a list of the possible functions.
Pedestrian start input - When SWITCH 8 is in the OFF position: N.O. contact. Press
the push-button connected to this input to command only one wing (pedestrian opening).
The single wing will follow the set operating mode and, when a start pulse is given, the
automation opens both wings, since the start function has priority over the pedestrian
start input. This pedestrian start input is ignored if the automation has been commanded