9) Instructions for personalised automation operation
SECTION 2 describes how to personalise operation of the automation, by means of settings and options to be memorised in the control unit.
The final section is dedicated to troubleshooting, maintenance and disposal of the product.
9.1) Programming keys
The SOON control unit is fitted with 3 keys which can be used both for the control of
the unit during testing and the programming pro-cedure:
OPEN
The "OPEN" key enables the user to open the door or scroll up through
▲
the programming steps
STOP
The "STOP" key enables the user to stop the manoeuvre, or when pressed
SET
for 5 seconds enables access to programming mode.
CLOSE
The "CLOSE" key enables the user to close the door or scroll down
▼
through the programming steps
10) Settings
The SOON control unit is equipped with a number of programmable
functions; function settings are entered by means of the 3 keys on
the control unit: [▲] [Set] [▼] and are displayed by means of 8
leds: L1....L8.
The programmable functions available on SOON are divided into 2
levels:
10.1) Level 1 functions
Table 3: list of programmable functions: level 1
Led Function
L1
Automatic closure
L2
Close After Photo
L3
Always Close
L4
Stand-By
L5
Long inversion
L6
Preflashing
L7
Sensitivity
L8
Compensation
During normal operation of SOON, when no manoeuvre is in progress, leds L1....L8 are lit or off depending on the status of the associated
function, for example L1 is lit if the function "Automatic closure" is enabled.
12
Description
This function enables automatic closure of the gate after a set pause time; by default the Pause Time is set
at 30 seconds, but can be modified to 10, 20, 40, 60, 80, 120, 160 or 200 seconds.
If the function is disabled, operation is "semiautomatic".
This function enables the system to keep the door open only for the time required for transit, in fact activation of
"Photo" always causes automatic closure with a pause time of 5s (regardless of the set value)
The behaviour changes according to whether the function "Automatic closure" is enabled or disabled.
With "Automatic closure" disabled: the door always reaches the totally open position (even if Photo is
disengaged beforehand). On release of Photo, automatic closure is activated with a pause of 5s.
With "Automatic closure" enabled: the opening manoeuvre stops immediately after release of the
photocells and automatic closure is activated with a pause of 5s.
The function "Close After Photo" is always disabled in manoeuvres interrupted by means of a Stop
command. If the function "Close After Photo" is disabled, the pause time is as set; otherwise there is no
auto-matic closure if the function is disabled.
The function "Always Close" is activated, causing closure, when an open door is detected on restoral of
power supply. For safety reasons, the manoeuvre is preceded by a 3-second pre-flashing interval.
If the function is disabled, the door remains stationary on restoral of power.
This function enables reduction of consumption to a minimum. If this function is enabled, 1 minute after
completion of the manoeuvre the control unit turns off the BlueBUS output (and therefore the devices) and
all leds, with the exception of the BlueBUS led, which flashes at a slower speed. When the control unit
receives a command it restores full operating conditions. If the function is disabled, no reduction in
consumption is enabled.
This function enables the selection of the type of inversion executed by the door after activation of a STOP
command or the force limiter device. If the function is disabled, inversion is short (approx. 15cm). If the
function is enabled, inversion continues through to the maximum opening or closing position.
The pre-flashing function is added to a pause of 3s between activation of the flashing light and the start of
the manoeuvre to warn of a hazardous situation. If preflashing is disabled, activation of the flashing light
coincides with the start of the manoeuvre.
This function enables a significant increase in sensitivity of the motor for obstacle detection. If used in
support of detection of the impact force, the parameters "Speed" and "Motor force" must also be set in the
level 2 menu.
This function enables recovery of the extension over time of the metal tops of the door and is subordinate
to the use of a 8,2KΩ resistive type senstivie edge or OSE optic sensor.
12
Level 1: functions settable in ON-OFF mode (enabled or disabled);
in this case each led L1....L8 indicates a function, if lit the function
is enabled, if off the function is disabled; see Table 3.
Level 2: parameters settable on a scale of values (from 1 to 8); in
this case each led L1....L8 indicates a set value from the possible
8; see Table 4.