• Turn power off at the circuit breaker before installing the sensor
• Sensor must be installed and used in accordance with appropriate electrical codes and
regulations
• Installation by a qualifi ed electrician is recommended

Package Contents

• HBS 300-WL or HBS 200-WL
• Four 1/2 inch KO locknuts

Installation Overview

Needed for installation
• 3 wire nuts for termination
• Phillips head screwdriver
• A threaded female 1/2 inch conduit hub
(supplied by others) or STEINEL EM1
extender module may be required depending
on fi xture type.
Applications
• HBS 300-WL: Open area wet location where
360 coverage is needed
• HBS 200-WL: High bay aisle way wet location
areas
5
4
3
WARNING
• One rubber gasket
• One chase nipple
• Installation instructions
Intended uses
• For indoor use
• For individual fi xture lighting control
6
2
1
Front cover
4x screws
2
1
Gasket
3
Back box
4
Cable
5
Slotted cable gasket
6
- 2 -
HBS 300-WL Product Overview
120/230/277
PIR
VAC
50/60Hz
Product description
The HBS 300-WL sensor provides effective
lighting control in high bay open area wet
location applications such as unconditioned
storage warehouses. It mounts directly to a
Specifi cations
Voltage
120/230/277 VAC, 50/60 Hz
Load rating
120 VAC: 0-800 watt ballast or tungsten - 1/4 hp
230/277 VAC: 0-1200 watt ballast
Time delay
15 sec to 30 min
Light level
.2 - 200 footcandles ; 2 - 2000 lux
Coverage
360°, up to 22 ft (6.7 m) radial reach,
up to 60 ft (18.2 m) tangential reach
Environment
IP65, wet location rated, -4°F to +104°F, -20°C to +40°C
Dimensions
5.54 x 4.54 x 2.86 in; 115.3 x 115.3 x 72.7 mm
nipple length .58 in, 14.7 mm
5 year warranty
UL and CUL Listed, RoHS Compliant
1
2
3
4
1
1/2 inch threaded nipple
2
Lock nuts
Time delay setting DIP switch
3
Light level trimpot
4
Detection lens
5
Fixture
IP65
or J Box
Wet
Mount
Location
360°
high / low bay lighting fi xture or to a junction box.
A threaded female 1/2 inch conduit hub (supplied
by others) or STEINEL EM1 extender module may
be required depending on fi xture type.
10ft/3m
20ft/6.1m
30ft/9.1m
40ft/12.2m
50ft 40ft
35ft
35ft
15.2m12.2m
10.7m
10.7m
22ft
22ft
6.7m 6.7m
5
- 3 -
40ft
50ft
12.2m
15.2m

Publicidad