HBS 200-WL Product Overview
120/230/277
PIR
VAC
50/60Hz
Product description
The HBS 200-WL sensor provides effective light-
ing control in high bay aisle way applications.
The sensor contains two dual-element pyro-
electric detectors and is engineered to perform
Specifi cations
Voltage
120/230/277 VAC, 50/60 Hz
Load rating
120 VAC: 0-800 watt ballast or tungsten - 1/4 hp
277 VAC: 0-1200 watt ballast
Time delay
15 sec to 30 min
Light level
.2 - 200 footcandles ; 2 - 2000 lux
Coverage
100 x 13 ft (30.48 x 3.96 m) linear detection
Environment
IP65, wet location rated, -4°F to +104°F, -20°C to +40°C
Dimensions
5.54 x 4.54 x 2.98 in; 115.3 x 115.3 x 75.8 mm
nipple length .58 in, 14.7 mm
5 year warranty
UL and CUL Listed, RoHS Compliant
1
2
3
4
1
1/2 inch threaded nipple
4
Light level trimpot
2
Lock nuts
5
Detection lens
Time delay setting DIP switch
3
IP65
Fixture
Aisle
Wet
or J Box
way
Location
Mount
at a wide range of mounting heights, up to 45 feet
(13.7 m). It mounts directly to a high bay lighting
fi xture or junction box.
10ft/3m
20ft/6.1m
30ft/9.1m
40ft/12.2m
50ft
50ft
15.2m
15.2m
53ft
53ft
16.2m
16.2m
5
radial
tangential
The HBS 200-WL has an aisle way coverage of
up to 100 feet when mounted at 40 ft.
- 4 -
Operation HBS 300-WL, HBS 200-WL
The HBS 300-WL and HBS 200-WL operate by
turning lights ON automatically when occupancy
is detected and OFF when the space is left
vacant and the time delay has elapsed.
Light level function
The light level (Hold OFF) feature keeps lighting
OFF during daylight hours, regardless of
occupancy.
Initial power up
Upon initial power up, the load will turn ON for up
to one minute. If no motion is detected, the load
will switch OFF. If motion is detected and the
target light level setting is less than the daylight
level, the load will stay ON for the selected time
delay setting (per DIP switch setting). If the
daylight level at power up is greater than the
target light level setting, the load will switch OFF
regardless of occupancy.
Surge protection
The surge protection feature will reset the
sensor automatically after: power surges, power
outages, and power shortages. Surge protection
protects the sensor if it is miswired as well. If
miswired, shut off power, correct the wiring, and
the sensor will then operate correctly.
Mounting
Placement guidelines -
HBS 300-WL, HBS 200-WL
• A threaded female 1/2 inch conduit hub
(supplied by others) or STEINEL EM1 extender
module may be require depending on fi xture
type.
• Detection lens must have a clear, unob-
structed view of controlled area and must
project beyond the lamps.
• Sensor should be 6 to 8 feet away from
heating/cooling supply ducts.
• Mounting height is up to 45 feet.
• Must be mounted on a stable platform.
End of fi xture mounting -
HBS 300-WL, HBS 200-WL
The HBS 300-WL or HBS 200-WL typically
mount to a 1/2" knockout at the end of a high/
low bay water tight fi xture using an EM1 extender
module. The sensor's lens should be mounted
below the bottom edge of the fi xture.
2
4
Fixture
1
3
Sensor
EM1
1
Rubber gasket
2
Chase nipple
3
Slotted cable gasket
4
The EM1 Extender Module is recommended for
use with the HBS 300-WL and HBS 200-WL if
the knockout at the end of the fi xture is located
greater than 1/2" from the bottom edge of the
fi xture. Pull the slotted cable gasket through the
chase nipple until it snaps in to place creating a
water tight seal.
- 5 -