SAFETY INSTRUCTIONS 1.3. Motors must be wired for proper voltage. Motor wiring diagram is on motor nameplate. Wire size TO AVOID SERIOUS OR FATAL PERSONAL must limit maximum voltage drop to 10% of name- INJURY OR MAJOR PROPERTY DAMAGE, READ plate voltage at motor terminals, or motor life and AND FOLLOW ALL SAFETY INSTRUCTIONS IN pump performance will be lowered.
3.3. If larger pipe is required, an eccentric pipe reducer 5.1.2. Three-phase motor: Interchange any two (with straight side up) must be installed at the pump. power supply leads. 3.4. Installation with pump below source of supply: 6. OPERATION 3.4.1. Install full flow isolation valve in piping for 6.1.
9.3. Reassembly is the reverse of disassembly. 10. TROUBLE SHOOTING CHART 9.4. Observe the following when reassembling the liquid- end: MOTOR NOT RUNNING (See causes 1 through 6) 9.4.1. All mechanical seal components must be in good condition or leakage may result. Re- LITTLE OR NO LIQUID DELIVERED placement of complete seal assembly, when- (See causes 7 through 17)
PARTS LIST MECHANICAL SEAL APPLICATION CHART Item No. Description Materials Rotary Stationary Elastomers Metal Parts Part No. Casing Ceramic BUNA 18-8SS 10K10 AISI 316L SS Impeller Carbon EPR 10K18 Motor adapter Steel Viton 10K55 Silicon 316SS Carbide 123 Deflector BUNA-N EPR 10K81 Silicon Carbide...
INSTRUCCIONES DE SEGURIDAD códigos eléctricos locales y nacionales. Instale un interruptor de desconexión de todo el circuito cerca PARA EVITAR LESIONES PERSONALES GRAVES O de la bomba. FATALES, Y DAÑOS SIGNIFICATIVOS A LA PROPIE- DAD, LEA Y SIGA TODAS LAS INSTRUCCIONES Siempre desconecte la alimentación eléctri- PRECAUCIÓN DE SEGURIDAD QUE SE ENCUENTRAN EN ESTE...
2.7. La base de montaje debe ser plana y sólida para 3.7. Use 3 ó 4 vueltas de cinta de teflón para sellar las eliminar la deformación al ajustar los bulones. Use conexiones roscadas. monturas de goma para minimizar el ruido y la vibración.
8.4.2. Retire el conjunto retractable posterior de 9.5. Inspeccione la unidad rearmada en busca de ligadu- la carcasa (100) ras y efectúe las correcciones necesarias. 9.6. Ajuste los bulones de la carcasa alternadamente 8.4.3. Retire la contratuerca del impulsor (304) trazando una estrella para evitar que el anillo en O se ligue.
LISTA DE PARTES CUADRO DE APLICACIÓN DEL SELLO MECÁNICO Ítem No. Descripción Material Rotativo Estacionario Elastómeros Partes metálicas Parte No. 100 Carcasa Cerámica BUNA Acero inox. 18-8 10K10 Acero inox. 316L AISI Impulsor Carbono EPR 10K18 108 Adaptador del motor Acero Carburo de Vitón Acero inox. 10K55 silicio 316 123 Deflector BUNA-N...
CONSIGNES DE SÉCURITÉ On doit toujours couper le courant ATTENTION lorsque l’on effectue quelque travail que AFIN DE PRÉVENIR LES BLESSURES GRAVES OU ce soit sur la pompe ou sur les commandes. MORTELLES ET LES DOMMAGES MATÉRIELS IMPORTANTS, LIRE ET SUIVRE TOUTES LES 1.3.
2.7. L’assise doit être plane et solide pour empêcher 3.6. Le diamètre (D) et la hauteur d’immersion (H) de que le serrage des boulons ne cause de contraintes. l’orifice d’entrée du tuyau d’aspiration doivent être Monter l’appareil sur caoutchouc pour réduire le suffisants pour empêcher l’aspiration d’air par vortex bruit et les vibrations au minimum.
8.4. Tête de pompage 9.5. Une fois la pompe remontée, vérifier s’il y a grip- page. Apporter les corrections nécessaires. 8.4.1. Enlever les vis de fixation (370) du corps de pompe. 9.6. Serrer les vis de fixation du corps de pompe en étoile pour prévenir le coincement du joint torique.
TABLE DES GARNITURES (JOINTS) MÉCANIQUES LISTE DE PIÈCES Élément mobile Élément fixe Élastomères Métal de pièce d’article Description Matériau Céramique Buna Inox 18-8 10K10 Corps de pompe Inox AISI 316L Carbonoe Éthyl.-propyl. 10K18 101 Roue (impulseur) Carbure de Viton Inox 10K55 108 Adaptateur de moteur Acier silicium 316 Carbure de Éthyl.-propyl.
Declaration of Conformity Declaration of Conformity We at, Goulds Water Technology/Xylem Inc. 1 Goulds Drive Auburn, NY 13021 Declare that the following products: NPE, MCS, MCC, 3656, 3656 SP , GB, e-SV , SVI, NPO, Prime Line SP , HB, HMS, LC, NPV , LB, LBS comply with Machine Directive 06/42/EC. This equipment is intended...