SAFETY INSTRUCTIONS 1.3 Motors must be wired for proper voltage. Mo- tor wiring diagram is on motor nameplate. Wire TO AVOID SERIOUS OR FATAL PERSONAL size must limit maximum voltage drop to 10% of INJURY OR MAJOR PROPERTY DAMAGE, READ nameplate voltage at motor terminals, or motor AND FOLLOW ALL SAFETY INSTRUCTIONS IN life and pump performance will be lowered.
3.2 Suction pipe must be at least as large as the suc- 5. ROTATION tion connection of the pump. Smaller size will 5.1 Correct rotation is right-hand (clockwise when degrade performance. viewed from the motor end). Switch power on 3.3 If larger pipe is required, an eccentric pipe reducer and off quickly.
NOTE: Further disassembly will require TROUBLESHOOTING removal of the mechanical seal. It is recom- SYMPTOM mended that a new mechanical seal be installed at reassembly. MOTOR NOT RUNNING See Probable Causes 1 thru 6 8.2.6 Lubricate the shaft and mechanical seal with soapy water.
MANUAL DE INSTRUCCIÓN IM064R07 Modelo LB INSTRUCCIONES DE INSTALACIÓN, FUNCIONAMIENTO Y MANTENIMIENTO...
Página 9
TEMA PÁGINA Instrucciones de Seguridad ..............................10 Notas Importantes ................................10 Instalación ..................................... 10 Tubería de Succión ................................11 Tubería de Descarga ................................11 Rotación ....................................11 Operación ..................................... 11 Mantenimiento ..................................11 Desmontaje ..................................12 Montaje ....................................12 Identificación y Resolución de Problemas ........................12 Tabla de Componentes de las bombas LB........................
INSTRUCCIONES DE SEGURIDAD cales y nacionales. Instale un interruptor de descon- exión de todos los circuitos cerca de la bomba. PARA EVITAR LESIONES PERSONALES GRAVES O FATALES, Y DAÑOS SIGNIFICATIVOS A LA SIEMPRE DESCONECTE EL SUMINIS- PRECAUCIÓN PROPIEDAD, LEA Y SIGA TODAS LAS INSTRUC- TRO ELÉCTRICO ANTES DE TRABA- CIONES DE SEGURIDAD QUE SE ENCUENTRAN JAR SOBRE LA BOMBA O LOS CONTROLES.
NO INSTALAR CON EL MOTOR POR 3.5.3 La válvula de pie se debe utilizar únicamente si PRECAUCIÓN DEBAJO DE LA BOMBA. CUALQUIER es necesario para cebar la bomba, mantener el PÉRDIDA O CONDENSACIÓN AFECTARÁN AL cebado o en casos de servicio intermitente. MOTOR.
EL LÍQUIDO BOMBEADO PROVEE 9.4 El proceso de reensamble es inverso al de des- PRECAUCIÓN montaje. Al volver a armar la bomba, preste aten- LA LUBRICACIÓN. SI LA BOMBA SE ción a lo siguiente. HACE FUNCIONAR EN SECO, LAS PARTES ROTA- TIVAS SE AGARROTARÁN Y SE DAÑARÁ...
TABLA DE COMPONENTES DE LAS BOMBAS LB Ítem No. Descripción Materiales Códigos de motor 1Ø – ODP 3Ø – ODP 1Ø – TEFC 3Ø – TEFC Tapón Acero inox. 304 Anillo en O - tapón ½ SFE04853 SFE04873 SFE04821 SFE04876 Tornillo de cabeza hueca Acero inoxidable 410, ¾...
CONSIGNES DE SÉCURITÉ ON DOIT TOUJOURS COUPER LE ATTENTION COURANT LORSQUE L’ON EFFECTUE AFIN DE PRÉVENIR LES BLESSURES GRAVES OU QUELQUE TRAVAIL QUE CE SOIT SUR LA POMPE MORTELLES ET LES DOMMAGES MATÉRIELS OU LES COMMANDES. IMPORTANTS, LIRE ET SUIVRE TOUTES LES CONSIGNES DE SÉCURITÉ...
2.7. L’assise doit être plane et solide pour empêcher 3.6. Le diamètre (d) et la hauteur d’immersion (h) de que le serrage des boulons ne cause de contraint- l’orifice d’entrée du tuyau d’aspiration doivent es. Monter l’appareil sur caoutchouc pour réduire être suffisants pour empêcher l’aspiration d’air par le bruit et les vibrations au minimum.
10. DIAGNOSTIC DES ANOMALIES 8. DÉMONTAGE 8.1. Le démontage complet de la pompe est décrit ci- ANOMALIE dessous. Ne démonter que ce qui est approprié à l’entretien nécessaire. NON-FONCTIONNEMENT DU MOTEUR 8.1.1. Couper le courant. (V. causes probables 1 à 6) 8.1.2.
TABLE DE COMPOSANTS DU MODÈLE LB N o d’article Description Matériaux Codes de moteur Bouchons Inox 304 1Ø – ODP 3Ø – ODP 1Ø – TEFC 3Ø – TEFC Joints toriques (bouchons) ½ SFE04853 SFE04873 SFE04821 SFE04876 Vis à tête creuse Inox 410 nickelé...
Declaration of Conformity We at, Goulds Water Technology/Xylem Inc. 1 Goulds Drive Auburn, NY 13021 Declare that the following products: NPE, MCS, MCC, 3656, 3656 SP, GB, e-SV, SVI, NPO, Prime Line SP, HB, HMS, LC, NPV, LB, LBS comply with Machine Directive 06/42/EC. This equipment is intend-...