SL24.W
State on power up
Gate in closed position:
The
first
step-step
opens the gate.
Gate in open position:
L4
The first step-step command clos-
es the gate. If automatic closing is
on, after the pause time the gate
closes
Apartment block
Apartment block function off
Does not close and stop in
opening
L5
Does not close and stop in open-
ing and pause
Does not close and stop in open-
ing, pause and closing
Rapid closing
Rapid closing function off
Rapid closing in gate mode:
The control panel starts to count
the clearance time (L7) from when
the closing photocell is released,
when the clearance time expires it
closes again.
Rapid closing in barrier mode:
The control panel starts to count
L6
the clearance time (L7) from
when the closing photocell is
released, and when the clearance
time expires it closes again. If
the closing photocell is occupied
again, it gives a stop command.
When released again it continues
with closing. The closing photocell
returns to normal operating after
complete closure.
Clearance time (adjustable at
intervals of 1 s)
Time after which the gate closes
L7
again if the rapid closing (L6) is on
Minimum clearance time
Maximum clearance time
Pre-flash
Flashing time of the flashing light
before the gate starts to move
L8
Pre-flash disabled
3 s pre-flash
4 s pre-flash
5 s pre-flash
20
(OP)
command
CL
OP
(OFF)
OFF
1
2
3
(OFF)
OFF
1
2
(2)
1
10
(OFF)
OFF
3
4
5
EN
Manned
Manned function off
Step-step command disabled,
remote controls not working. The
control panel accepts only open
L9
and close commands
Emergency manned. In normal
standard operating conditions,
with the safety devices occupied it
works as manned.
Step by step
Step-step command operates in
2 steps:
open, close, open...
Step-step command operates in
L10
3 steps:
open, stop, close, open...
Step-step command operates in
4 steps:
open, stop, close, stop, open...
Stop from step-step
Automatic closing disabled when
a stop command from step-step
L11
is given
Automatic closing not disabled
when a stop command from step-
step is given
Stop from stop
Automatic closing disabled when a
stop command from stop is given
L12
Automatic closing not disabled
when a stop command from stop
is given
Operation in battery
Standard operation
Normal operation with flashing
light disabled
L14
After a re-open command it stays
open
When the main power supply is
cut off it opens and remains open
Economy
Standard operation
Economy operation on. With the
gate closed, it switches off the
L15
accessory power supply on outputs
1 and 2. The outputs are powered
again following a new command.
(OFF)
OFF
1
2
(4)
2
3
4
(ON)
OFF
ON
(ON)
OFF
ON
(1)
1
2
3
4
(OFF)
OFF
1