Vimar Elvox SL24.W Guía Rápida Para El Instalador página 20

Ocultar thumbs Ver también para Elvox SL24.W:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
SL24.W
Terminal A2 output type
Output off
Gate open warning light (SCA)
Operation as per SCA parameter
setting
Auxiliary Radio output (RAU)
Operation as per RAU parameter
setting
Courtesy light (LCO)
On during leaf movement and for
the amount of time after the leaf
A2
stopping set in parameter LCO
Zone light (LZO)
On during leaf movement
Gate left open (OAB)
On if the gate remains open for a
time longer than that defined by
the open gate alarm logic (L16)
Maintenance (MAN)
Output off when the number of
maintenance signalling manoeu-
vres (MNPS) is reached in the
diagnostics section
Synchronization output, com-
pass type interlock (INB)
Automatically configures input S4
as synchronization input without
any choice by the user.
The control panel consents to the
gate opening only if the other gate
is in the closed position.
Synchronization output, com-
pass type interlock (INP) with
A2
presence signal.
Automatically configures input
S4 as synchronization input and
S3 as presence input without any
choice by the user.
The control panel consents to the
gate opening only if the other gate
is in the closed position and the
presence input is occupied.
Auxiliary Radio Output Config-
uration
Impulsive: the output is active for
1 s following the RAU command
from the remote control
RAU
Timed: the output is active for the
time set in the RAUT parameter
following the RAU command from
the remote control
Bistable: the output works in
Step-Step ON/OFF mode
18
RAU output timing
(2)
1 s (minimum time)
OFF
RAUT
600 s (maximum time)
1
Courtesy light timer
1 s (minimum time)
LCO
300 s (maximum time)
2
SCA output operating mode
Gate closed: off
Gate open: on fixed
Gate closed: off
3
Gate moving: intermittent
Gate open: on fixed
4
Indeterminate position: intermittent
SCA
pause of 1 s every 5
Gate closed: off
5
Gate opening slow intermittent
Gate open on fixed
Gate closing intermittent
Indeterminate position: intermittent
pause of 1s every 5
6
Gate stopped on fixed
Gate moving off
SCA
Gate closed off
Gate moving on fixed
Input configuration
Sub
Description
menu
7
C1/C2/C3/C4 command input
Step-step (PP)
The step-step control:
- with the gate stopped and closed,
opens the gate
- in opening, stops or closes the
gate according to the step-step
logic setting (L10)
8
- with the gate stopped after
opening, closes the gate
- in closing, stops or opens the gate
C(X)
according to the step-step logic
setting (L10)
- with the gate stopped after clos-
ing, opens the gate
(1)
Pedestrian (PED)
Opens the gate to the pedestrian
1
position
It acts like a step-step if the
command is given with the gate in
a position beyond the pedestrian
2
position
3
EN
(1)
1
600
(120)
1
300
(1)
1
2
3
4
5
Values
(default)
1
(C1)
2
(C2)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Elvox sl24.w

Tabla de contenido