SL24.W
Motor parameters
Sub
Description
menu
Type of actuator used
O1
Not set
Acto 600D (ESM2)
Type of position control
Automatically set with the choice
of actuator. You are advised not
to change the setting given by the
type of actuator.
O2
Virtual encoder: the control
panel calculates the gate position
using the electric motor operating
parameters
Encoder for Acto 600D (ESM2)
Type of limit switch on opening
Automatically set with the choice
of actuator. You are advised not
to change the setting given by the
type of actuator.
No limit switches on opening:
the electric motor stops at the end
O3
of the working time
Stop limit switch on opening:
the limit switch stops the motor
Limit switch in proximity
opening: the limit switch allows
the manoeuvre to continue at the
approach speed set until it detects
the mechanical stop
Type of limit switch on closing
Automatically set with the choice
of actuator. You are advised not
to change the setting given by the
type of actuator.
No limit switches on closing:
the electric motor stops at the end
O4
of the working time
Stop limit switch on closing: the
limit switch stops the motor
Limit switch in proximity
closing: the limit switch allows
the manoeuvre to continue at the
approach speed set until it detects
the mechanical stop
Note:
O2, O3, O4 are automatically set with the choice of actua-
tor. You are advised not to change the setting given by the
type of actuator.
VIMAR group
Motor travel calibration procedure
Values
Rapid travel calibration.
(default)
The calibration is done fully automatically
(1)
and sets:
OFF
- The slowdown in opening at 20% of the
1
- The slowdown in closing at 20% of the total
(3)
- Pedestrian opening at 30% of the total
Button
-
2
LRNE
PP
3
(1)
-
-
OFF
-
-
1
-
Advanced travel calibration.
2
The calibration allows the installer to
choose:
- Slowdown position in opening
- Slowdown position in closing
- Pedestrian opening position
(1)
Button
-
LRNA
OFF
PP
1
-
2
PP
LRNA
-
-
-
-
EN
total travel
travel
travel
Msg on
Phase description
display
PP
Wait for start of cali-
bration procedure
CL 1
When button
pressed: closing and
search for closing
limit switch
OP 1
Opening travel mea-
surement
CL 1
Closing travel mea-
surement
OPC1
Opening current
curve reading
CLC1
Closing current curve
reading
END
End of procedure
Msg on
Phase description
display
PP
Wait for start of cali-
bration procedure
CL 1
When button
pressed: closing and
search for closing
limit switch
CL 1
Continuation of open-
ing and slowdown
speed up to closing
limit switch
OPED
Start pedestrian
opening.
When button
pressed: pedestrian
opening position
setting
CPED
Leaf closing from
pedestrian opening
position
OPC1
Opening current
reading
CLC1
Closing current
reading
END
End of procedure
15