List of signalling on the display
Signal
Description
C1
Contact closed on command C1 input
C2
Contact closed on command C2 input
C3
Contact closed on command C3 input
C4
Contact closed on command C4 input
S1
Contact open on safety device S1 input
S2
Contact open on safety device S2 input
S3
Contact open on safety device S3 input
S4
Contact open on safety device S4 input
FO1
Opening limit switch position reached
FC1
Closing limit switch position reached
OBO
Obstacle detected on opening
OBC
Obstacle detected on closing
Motor in stop approach force reduction
AF1
interval
MSO1
Mechanical stop reached in opening
MSC1
Mechanical stop reached in closing
Operation with battery
When this message is displayed it is fol-
BATT
lowed by an indication of the battery oper-
ating voltage, e.g. 24.5V
Battery almost flat (indication shown only
BT-
when the gate is stopped)
Battery totally flat (indication shown only
BT--
when the gate is stopped)
Radio command received from saved re-
RX
mote control
Radio command received from unsaved
NX
remote control button
RD
Rolling/fixed code decoding off
OAB
Gate left open
AT
Gate in self-calibration

List of alarms

Alarm
Description
XXXX
Reset card
Manoeuvre interval since last maintenance
MNP
reached alarm
F0
Error motor not selected
F1
Motor cables inverted error
F3
Reversed limit switch error
F4
Both open limit switch alarm
F5
Opening limit switch malfunction error
F6
Closing limit switch malfunction error
F9
Communication error with expansion card
F10
Error alarm motor not connected
F12
Encoder error alarm
Microswitch undervoltage (check power sup-
F14
ply and outputs)
F15
Safety test 1 failed
F16
Safety test 2 failed
24
F17
Safety test 3 failed
F18
Safety test 4 failed
F19
Manoeuvre length/timeout alarm
F21
Mosfet short alarm
F23
Blocked rotor alarm
F26
5th obstacle in closing alarm
F27
Overcurrent alarm
F29
Radio memory full alarm
F30
Faulty radio memory alarm
F31
Short flashing alarm
F32
Gate open light short alarm
F33
No memory card alarm
F34
FW checksum alarm

Firmware Updating

To update the control panel firmware, run the
following procedure
Step
Description
Load the required firmware file on a USB mem-
1
ory stick
2
Disconnect the power supply to the control panel
Insert the USB memory stick in the USB connec-
3
tor on the control panel
4
Press buttons ESC and OK at the same time
Without releasing the buttons, power up the con-
5
trol panel
Keep pressing ESC and OK
6
7
After 3 s, the control panel displays PRG USB
8
Release the buttons
Press OK
9
Use buttons ▲ and▼ to select the required firm-
10
ware file to load. The file is displayed with the
firmware version
11
Press OK to confirm
12
The display shows "oooo" during programming
13
The display will show DONE. End of procedure
Press ESC. The LED on the display module will
14
start flashing. When it stops flashing, the card
reboots.
15
Remove the USB memory stick
EN