SL24.W
Open (OPEN)
The open command:
- with the gate stopped and
closed, opens the gate
- in opening is ignored
- with the gate open, resets the
pause time
- with the gate stopped, opens the
gate
- in closing, opens the gate
Close (CLS)
The close command:
- with the gate stopped and
closed, is ignored
C(X)
- in opening, closes the gate
- with the gate stopped, closes
the gate
- in closing is ignored
Timer (TIM)
The timer command:
- when closed, opens the gate
and keeps it open as long as the
contact remains closed
- when the contact is released it
closes the gate
Pedestrian Timer (TIMP)
Has the same function as the tim-
er command but on the pedestrian
position
S1/S2/S3/S4 safety input
Off
Photocell closing (PHC)
The closing photocell:
- with the gate stopped, allows
the gate to open
- in opening does not intervene
- with the gate open, does not
allow it to close and when re-
leased will reset the pause time
- in closing, reopens the gate
immediately
S(X)
Photocell (PH)
The photocell:
- with the gate stopped, does not
allow the gate to open
- during opening stops the
movement and when released
proceeds with opening
- with the gate open, does not
allow it to close and when re-
leased will reset the pause time
- in closing stops the movement
and when released reopens the
gate
VIMAR group
Opening photocell (PHO)
The opening photocell:
- with the gate stopped, allows
- in opening, recloses it completely
3
- with the gate open, allows it to
(C3)
- in closing does not intervene
Sensitive edge with
NC clean contact (BAR)
- with the gate stopped, does not
- in opening disengages
4
- with the gate open, does not
(C4)
- in closing disengages
8.2 KΩ balanced sensitive edge
(8K2)
Same behaviour as the NC sensi-
tive edge
5
S(X)
Stop (STP)
- stops the gate
Interrupts the automatic closing
as per the logic stop setting from
stop (L12)
6
Photocell closing checked
(PHC)
As per closing photocell but with
OFF
check
Photocell checked (PHT)
(S3 S4)
As per photocell but with check
Photocell opening checked
(PHC)
As per opening photocell but with
check
1
NC sensitive edge checked
(S1)
(BART)
As per KΩ NC sensitive edge but
with check
8.2 KΩ balanced sensitive edge
checked (8K2T)
As per 8.2 KΩ sensitive edge but
with check
Control panel logic settings
Sub
Description
menu
2
Automatic closing
(S2)
L1
Automatic closing off
Automatic closing on
Pause time
1 s (minimum time)
L2
180 s (maximum time)
Pedestrian pause time
1 s (minimum time)
L3
180 s (maximum time)
EN
the gate to open
close and does not reset the
pause time
allow the gate to open
allow it to close and when re-
leased will reset the pause time
3
4
5
6
7
8
9
10
11
Values
(default)
(ON)
OFF
ON
(30)
1
180
(20)
1
180
19