Fireplace Installation
installation does not obscure the
air intake slots on top of unit in
any manner.
Keep a minimum of a 4" (102
mm) clearance from top of
unit to any surface or mate-
rial.
3. Wire a dedicated, properly
fused circuit with 120 Volt,
15 Amp rating. Allow up to
8' (2.44 m) of service cable
for connecting power supply
to junction box on fireplace
when installing after finishing
wall.
CAUTION: Use a two conduc-
tor, non-metallic sheath cable with
ground wire (three wires total) for
the incoming power supply on
fireplace inserts.
Use the appropriate wire to meet
local and national electrical codes
for rated power consumption.
Figure 5
32"
(813
mm)
4. Remove the outer jacket and
strip the individual conductor
from the end.
5. Loosen the screw securing
the junction box cover and
remove the cover.
6. Take the cables out from the
junction box, loosen the two
wire nuts and remove the
cord set (Figure 6).
7. Route the power supply wire
through the knockout on sup-
plied alternative junction box
cover and secure with a wire
clamp (not supplied) (Figure
7).
8. Connect the black wire (live)
from the unit to the black wire
from power supply (Figure 7).
9. Connect the white wire (neu-
tral) from the unit to the white
wire from power supply
(Figure 7).
10. Connect the green wire
(ground) from the unit to the
green wire from power supply
(Figure 7).
11. Place all connectors inside
the unit and secure the junc-
tion box cover to unit. Ensure
that the cable clamp grips
only the jacket of service